PubMed Health⌕ Search

PubMed · 6885450

The equilibrium factor F.

Abstract

Consideration of the equilibrium factor F between the concentration of the radon daughters and the concentration of radon is a part of the evaluation of the measurements of radon daughter concentrations in dwellings when applying limits. Measurements of radon, radon daughters and air exchange rates have been carried out in 225 dwellings in Sweden. The F-factors have been compared with the theoretical model described by Wicke, taking into account the wall effect. The parameters of the model are discussed. The situation of the dwelling and the habits of the occupants can be expected to have the greatest importance for the F-factors although the ventilation rate is usually the most important modifying factor. For low air exchange rates (l less than 0.30 hr-1) the probability that the F-factors were between 0.28 and 0.74 was 95% calculated according to the t-distribution. The arithmetical mean was found to be 0.51. For air exchange rates close to the average rate (0.30 less than l less than 0.60 hr-1), the F-factors were between 0.21 and 0.66 with a mean of 0.43, and for high air exchange rates (l greater than 0.60 hr-1) the F-factors were between 0.21 and 0.47 with a mean value of 0.33.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Swedjemark. 1983. The equilibrium factor F.. https://doi.org/10.1097/00004032-198308000-00021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radon and thoron parallel measurements in Hungary.

Hungarian detectors modified and developed at the National Institute of Radiological Sciences (NIRS), Japan were placed at different sites, including homes and underground workplaces in Hungary, in order to gain information on the average radon (222Rn) and thoron (220Rn) concentration levels. Measurements were carried out in dwellings in a village and a manganese mine in Hungary. The radon and thoron concentrations in the dwellings of the village in the summer period were found to be 154 (17-1083) and 98 (1-714) Bq m(-3), respectively. Considering the results of other radon measurements during the winter (814 Bq m(-3)) and summer (182 Bq m(-3)) periods, the thoron concentrations were also expected to be higher in winter. In the manganese mine, radon and thoron were measured at 20 points for 6 months, changing the detectors each month. The averages were 924 (308-1639) and 221 (61-510) Bq m(-3) for radon and thoron, respectively. These results showed significant variance with the date and place of the measurement.

Housing↗