PubMed Health⌕ Search

PubMed · 6942641

Determination of electrolytes--methodological problems.

Abstract

To avoid errors in plasma potassium determination clenching of the fist should be avoided and heparinized blood should be used. The patient should be fasting and samples taken at the same time of the day. When evaluating intracellular potassium from plasma potassium acid based status should be considered. The clinical status should also be considered, since severely ill patients may have a low transmembrane potential leading to loss of cell potassium and increase in plasma potassium. Measurements of exchangeable sodium and potassium with radioactive tracers of whole body potassium (40K) are inprecise for determination of absolute cellular concentrations but more suitable for longitudinal studies. Determination of red cell electrolytes is of limited value, since these cells are not typical for the body cells. Electrolyte determination in leukocytes may give more accurate information. Muscle water and electrolytes can be determined in needle biopsy material. The concentration of intracellular electrolytes are expressed in relation to different bases of reference (FFS, GFFS, alkali-soluble protein, phosphorus, and intracellular water); the advantages and fallacies in using these references are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Bergström. 1981. Determination of electrolytes--methodological problems.. https://doi.org/10.1111/j.0954-6820.1981.tb02637.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Therapeutic drug monitoring of tacrolimus with the dried blood spot method.

In a preliminary investigation an assay for tacrolimus based on fingerprick sampling and consecutive application as a blood spot on sampling paper has been developed. The dried blood spot was analysed by HPLC-tandem mass spectrometry. The validated range was 1-30 microg/l. Intra- and inter-assay variability for precision and accuracy was <7.5% and 15%, respectively. Tacrolimus concentrations of 24 stable out patients were compared after both blood spot sampling and conventional venous sampling. Method agreement was investigated with the methods of Passing and Bablok and Bland Altman and proved suitable for clinical use. The dried blood spot method for tacrolimus seems promising for patient monitoring.

Blood Specimen Collection↗