PubMed · 6998706
Kidney storage at subzero temperatures using a hyperosmolar perfusate.
Abstract
32 dog kidneys were stored in a hyperosmolar perfusate (770 mosm/kg) at minus2 and plus4 degrees C, respectively, for 12-48 h and thereafter autotransplanted. 18 kidneys of the control group were stored in Collins solution at plus4 degrees C. The immediate function of the kidneys after transplantation was measured by p-aminohippuric acid and inulin clearances. Successful 24-hour preservation was possible by use of the hyperosmolar perfusate. Kidneys stored in the hyperosmolar perfusate at minus2 degrees C were better preserved than kidneys stored in Collins solution at plus4 degrees C. The addition of human albumin to the hyperosmolar perfusate did not improve the preservation results.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
R Grundmann, B Kaemmerer, D Helling, H Pichlmaier. 1980. Kidney storage at subzero temperatures using a hyperosmolar perfusate.. https://doi.org/10.1159/000128126. https://pubmed.health/record/pubmed%3A6998706/kidney-storage-at-subzero-temperatures-using-a-hyperosmolar-perfusate