PubMed Health⌕ Search

PubMed · 7013882

Development of school screening audiometry.

Abstract

It is now 50 years since serious attempts have been made to detect hearing impairment in school children, first by using the "Fading numbers gramophone audiometer" (in 1930-31) and later (in 1954) by the "Pure tone, sweep frequency, audiometric tests". There is good evidence to show (based to experience from this and many other countries) that by a properly organized screening programme, on the average, 6% of school children will be discovered to have significant hearing impairment and that without screening most of these will not be developed in this country unevenly and there are still many places where it is not practised properly or not at all. One of the reasons for this is the serious lack of understanding of the importance of screening by the authorities and, until recently, almost a complete lack of guidance by the Department of Health and Social Security. It is recommended also that systematic school-leaving audiometry should be introduced. The preventive and epidemiological significance of school leaving audiometry is stressed. Its potential importance in relation to industrial audiology is discussed. Impedance measurements are important but tests of middle-ear function should not be used as screening tests of hearing. First of all they are far too sensitive as a screening device and also it may lead to non-detection of many specific but significant sensorineural hearing losses (which are more frequent in children than generally assumed). However, it is hoped that eventually all children discovered to have a hearing loss, as a result of screening audiometry, will have a full test of middle-ear function. The two tests are complementary and not mutually exclusive.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Fisch. 1981. Development of school screening audiometry.. https://doi.org/10.3109/03005368109081420

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Bayesian estimation of intervention effect with pre- and post-misclassified binomial data.

We consider studies in which an enrolled subject tests positive on a fallible test. After an intervention, disease status is re-diagnosed with the same fallible instrument. Potential misclassification in the diagnostic test causes regression to the mean that biases inferences about the true intervention effect. The existing likelihood approach suffers in situations where either sensitivity or specificity is near 1. In such cases, common in many diagnostic tests, confidence interval coverage can often be below nominal for the likelihood approach. Another potential drawback of the maximum likelihood estimator (MLE) method is that it requires validation data to eliminate identification problems. We propose a Bayesian approach that offers improved performance in general, but substantially better performance than the MLE method in the realistic case of a highly accurate diagnostic test. We obtain this superior performance using no more information than that employed in the likelihood method. Our approach is also more flexible, doing without validation data if necessary, but accommodating multiple sources of information, if available, thereby systematically eliminating identification problems. We show via a simulation study that our Bayesian approach outperforms the MLE method, especially when the diagnostic test has high sensitivity, specificity, or both. We also consider a real data example for which the diagnostic test specificity is close to 1 (false positive probability close to 0).

Acoustic Impedance Tests↗

Abnormal electronystagmography in rheumatoid arthritis.

OBJECTIVE: Although sensorineural hearing loss has been widely investigated in those with rheumatoid arthritis, studies assessing the vestibular system in patients with rheumatoid arthritis are limited. The aim of this study was to assess the vestibular system in patients with rheumatoid arthritis. METHODS: The study consisted of 43 patients with rheumatoid arthritis and 30 healthy controls. Otorhinolaryngologic and neurotologic examinations, pure-tone audiometry, impedancemetry, electronystagmography including smooth pursuit, saccade, positional, and caloric tests were performed in all patients with rheumatoid arthritis and in controls. The erythrocyte sedimentation rate, C-reactive protein level, and rheumatoid factor level were evaluated in all patients with rheumatoid arthritis. RESULTS: Audiograms revealed sensorineural hearing loss in 12 patients (27.9%) with rheumatoid arthritis and in two controls (6.6%); the difference was statistically significant (P=.033). In those with rheumatoid arthritis, the results of electronystagmography revealed central abnormalities in nine patients (20.9%), peripheral abnormalities in three (6.9%), and mixed abnormalities in three (6.9%). Smooth pursuit and saccade tracing impairments were significantly higher in patients with rheumatoid arthritis (P>.05). Canal paresis in patients with rheumatoid arthritis were significantly higher than those in the control group (P=.039). No association was found between electronystagmographic abnormalities in patients with rheumatoid arthritis and age, sex, duration of disease, the results of laboratory testing, sensorineural hearing loss, or medication use. CONCLUSION: Our results suggest an association of rheumatoid arthritis with vestibular system dysfunction as well as auditory impairment.

Acoustic Impedance Tests↗

Reproducibility of sonotubometry as Eustachian tube ventilatory function test in healthy children.

OBJECTIVES: To devise a simple and reliable diagnostic procedure to test Eustachian tube function routinely in an ENT outpatient setting. One method to measure ET ventilatory function is sonotubometry. The reproducibility of a recently updated sonotubometry set-up was tested in healthy children. METHODS: The test population comprised 61 school children aged from 6 to 8 years. Only otologically healthy children were included. Health state was established by means of a 12-item questionnaire. To test reproducibility, sonotubometric testing took place in two sessions of 10 acts of swallowing each. Spearman's coefficient was used to test the correlation between the two sets of measurements. All testing took place at a primary school in a nearby village. RESULTS: Opening of the ET was recorded in at least one of the two measurement sessions in 82% of the children. The first and second sessions were highly correlated, with a Spearman's coefficient of 0.89. CONCLUSIONS: In otologically healthy children, opening of the ET was recorded frequently using the updated sonotubometry set-up. Measurement results had high reproducibility. Therefore, the test forms a useful method to assess ET ventilatory function in otologically healthy children. The performance of this updated version needs to be established in children with otological diseases.

Acoustic Impedance Tests↗