PubMed HealthSearch

PubMed · 7024526

Remounting multiple casting prior to final cementation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P M Walker. 1981. Remounting multiple casting prior to final cementation.. https://doi.org/10.1016/0022-3913(81)90297-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Low force cementation.

OBJECTIVES: The marginal adaptation of full coverage restorations is adversely affected by the introduction of luting agents of various minimum film thicknesses during the cementation process. The increase in the marginal opening may have long-term detrimental effects on the health of both pulpal and periodontal tissues. The purpose of this study was to determine the effects of varying seating forces (2.5, 12.5, 25 N), venting, and cement types on post-cementation marginal elevation in cast crowns. MATERIALS: A standardized cement space of 40 microns was provided between a machined gold crown and a stainless steel die. An occlusal vent was placed that could be opened or closed. The post-cementation crown elevation was measured, following the use of two commercially available capsulated dental cements (Phosphacap, and Ketac-cem Applicap). RESULTS: The results indicate that only the combination of Ketac-Cem Applicap and crown venting produced post-cementation crown elevation of less than 20 microns when 12.5 N seating force was used. Higher forces (25 N) and venting were required for comparable seating when using Phosphacap (19 microns). CONCLUSIONS: The amount of force required to allow maximum seating of cast crowns appears to be cement specific, and is reduced by effective venting procedures.

Cementation

Comparison of fatigue for three prefabricated threaded post systems.

Post designs may have a direct effect on fracture resistance of endodontically treated teeth. This in vitro study compared the resistance of three prefabricated threaded post systems with lateral shearing forces. After endodontics were completed, prefabricated posts were inserted according to the manufacturer's instructions. A silver amalgam core was placed, and extracted human teeth were prepared to a standard size with a 1 mm gingival chamfer finished on sound dentino A cast was fabricated and cemented, and the specimens were thermocycled. The test samples were secured to an Instron testing machine and loaded until failure. Fracture patterns were recorded, fractured surface areas were measured, and compressive stresses were calculated. However, there were no statistically significant differences among threaded posts in each test group.

Cementation

Inter- and intraobserver study of radiographic assessment of cemented total hip arthroplasties.

Radiographs are commonly used to identify loosened total hip prostheses. Interobserver and intraobserver variation was studied in an attempt to interpret 60 random pairs of radiographs with a time interval of 6 months to 12 years between the radiographs. Each of the four observers evaluated all pairs of radiographs independently, and the evaluations were repeated after 2 to 4 weeks. Each observer classified the femoral stem and the acetabular cup separately as stable or loose. Radiolucent lines of more than 2 mm were recorded. For the acetabular components, any change in inclination or migration was noted, and for the femoral components, subsidence or any change in varus or valgus of the stem was noted. There was considerable disagreement in observations of the acetabular component; agreement by all four observers was obtained in only 34 of 60 cases (57%). For the femoral component, agreement was obtained in 37 cases (62%). The observers agreed two and two (pairwise) on the acetabular component in 70 to 83% of cases and on the femoral component, in 72 to 82% of cases. Intraobserver variation was great with regard to the acetabular component, with kappa values ranging from 0.489 to 0.633. As to the femoral component, kappa values ranged from 0.737 to 0.800. Interpretation of radiographs of artificial hip arthroplasty is difficult, and comparisons between different series of implants should be made by the same person.

Cementation