PubMed HealthSearch

PubMed · 7068303

Fibronectin.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Stasko, R L De Villez. 1982. Fibronectin.. https://doi.org/10.1111/j.1365-4362.1982.tb00499.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An autologous fibrin tissue adhesive with greater bonding power.

OBJECTIVE: To describe and evaluate an autologous fibrin tissue adhesive (AFTA) that uses a combination of ethanol and freezing to precipitate fibrinogen (AFTA-E). DESIGN: The bonding power of AFTA-E was compared with that of a conventional AFTA based on ammonium sulfate precipitation of fibrinogen (AFTA-A). In this study, Silastic, porcine dermis, and human dura mater blocks were bonded together for 10 and 30 minutes with AFTA-E or AFTA-A. The blocks were then separated and the bonding power was measured. The efficacy of AFTA-E was also evaluated after a 24-hour refrigeration. SETTING: The Department of Otolaryngology Research Laboratory at the University of Illinois Eye and Ear Infirmary, Chicago, Ill. PARTICIPANTS: Blood was drawn from 86 healthy volunteers and AFTA-E and/or AFTA-A was manufactured. RESULTS: The AFTA-E was shown statistically to bond stronger than the AFTA-A. In addition, it was found that the efficacy of AFTA-E was unchanged after a 24-hour refrigeration. CONCLUSIONS: The improved AFTA, AFTA-E, is a superior alternative to the conventional AFTA-A. Furthermore, AFTA-E can be manufactured before surgery and stored, thus minimizing preparation time during surgery.

Adhesiveness

Augmentation of meniscal repairs with cyanoacrylate glue.

Cyanoacrylate glues are biodegradable, bacteriostatic, hemostatic adhesives which have been used experimentally in surgical procedures on many tissues. This study evaluates the efficacy of cyanoacrylate glues used for in vitro bovine meniscus repair. Our hypothesis was that a local adhesive might improve fixation of meniscus tears reapproximated with suture, or obviate the need for suture. Three high-viscosity flexible cyanoacrylate glues were tested and their tensile strengths compared to those of suture alone and suture augmented with glue. The flexible formulation enables the glue to deform with the meniscus during movement of the knee joint. Bovine meniscus tissue was used as the model to compare the tensile strength at the meniscus repair site using the 300 cps glue in combination with 3-0 prolene suture, 300 cps cyanoacrylate glue alone, and suture alone. Twenty specimens were included in each repair group, and the peak load to failure was normalized for surface area and subjected to analysis of variance. Results of the analysis showed that the peak load to failure of the combination of cyanoacrylate glue plus suture was significantly higher than that of glue alone (P < .0001), but not significantly higher than that of suture alone (P = .18). However, in tissues repaired with suture, tissue separation at the tear site was noted almost immediately after distraction started, as a result of the elasticity of the suture. The combination of cyanoacrylate glue plus suture provided the maximum tensile strength before tissue separation. Because tissue separation may interfere with the meniscal healing process, glue used in combination with suture appears to offer some advantage mechanically.(ABSTRACT TRUNCATED AT 250 WORDS)

Adhesiveness

Platelet and monoclonal antibody binding to fibrinogen adsorbed on glow-discharge-deposited polymers.

The state of fibrinogen adsorbed on untreated and glow-discharge-treated surfaces was examined by measuring platelet adhesion, monoclonal antibody (mAb) binding, the amount of fibrinogen adsorbed, and the amount of adsorbed fibrinogen which could be eluted with sodium dodecyl sulfate (SDS). Tetrafluoroethylene (TFE) glow-discharge-treated polymers have a lower surface free energy (in air) and retain a larger fraction of adsorbed fibrinogen than untreated surfaces after SDS elution. Platelet adhesion was lowest on the TFE-treated surfaces which retain the highest amounts of fibrinogen after SDS elution. Fibrinogen may undergo unfolding or spreading on the TFE-treated surfaces to minimize interfacial free energy (in water) and maximize protein-surface interactions. When it is adsorbed on the TFE-treated surfaces, fibrinogen evidently assumes a state which somehow prevents its recognition and binding by platelet receptors. Monoclonal antibodies that bind to the three regions in fibrinogen thought to be involved in platelet adhesion were therefore used to detect changes in adsorbed fibrinogen. These regions and the antibodies which bind to them are: the COOH-terminal of the gamma-chain, mAb M1; the RGD peptide sequence at A alpha 95-98, mAb R1; the RGD sequence at A alpha 572-575, mAb R2. For fibrinogen adsorbed on the untreated or TFE-treated surfaces, M1 and R2 binding was relatively high compared to background, while R1 binding was low. However, the amount of binding of each mAb to fibrinogen adsorbed on the TFE-treated surfaces was equal to or greater than fibrinogen adsorbed to the untreated surfaces. Therefore, antibody-detectable changes in the platelet binding regions of adsorbed fibrinogen that might have been caused by conformational or orientational rearrangements were not observed for the TFE-treated surfaces. The data suggest that the tight binding of fibrinogen on a surface may directly affect the ability of the fibrinogen to interact with the platelet receptors--i.e., that fibrinogen must be loosely held to facilitate maximal interaction with platelet receptors.

Adhesiveness