PubMed HealthSearch

PubMed · 7110920

Frame type socket for lower limb prostheses.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Volkert. 1982. Frame type socket for lower limb prostheses.. https://pubmed.ncbi.nlm.nih.gov/7110920/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.

During the next decade CAD/CAM technique will probably become routine in prosthetics and orthotics, not only as a complement to manual techniques, but also introducing new possibilities. However, even complex and sophisticated techniques have errors of measurement that must be considered. Such errors are of two principal kinds: systematic errors and random errors. In this study we have evaluated the Swedish CAPOD system with respect to volumetric determinations. We used two types of reference objects for volume determinations: cylinders and amputation residual limb models. Three different sizes were examined of each type of object. Volume measurements with CAPOD were compared with volumes obtained by water immersion or mathematical calculation (cylinders only). We found a constant, linear systematic error of +2.5%. Such an error can easily be corrected for. The random error, represented by the coefficient of variation, was 0.5%, which means that there is a theoretical possibility to detect volume changes exceeding 1%. We consider the precision sufficient for clinical practice in prosthetics and orthotics. Biological variations due to soft tissue deformation must be added on top of these errors. Such deformations were not evaluated in this study.

Artificial Limbs

Interface load analysis for computer-aided design of below-knee prosthetic sockets.

A finite-element analysis is made for the compression of soft tissues of the residual lower limb contained in a prosthetic socket. The analysis is relevant to static loading during stance in a patellar-tendon-bearing, below-knee design of socket. Values of Young's modulus are obtained experimentally for use in the model. One of the main objectives is to study the sensitivity of the loading to these values and also to other assumed conditions. Using direct pressure at the limb/socket interface and vertical stiffness as indicators, changes in material properties, socket alignment and socket rectification are investigated; assumptions about the frictional characteristic at the interface are seen to be critical in determination of load distribution. This type of analysis may provide the next stage of refinement for computer-aided socket design systems.

Artificial Limbs

Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

Artificial Limbs