PubMed HealthSearch

PubMed · 7146361

[Computer program for afterloading radiation planning].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Kobischke, M Spoddeck, K Bellstedt, M Tautz, R Jacob. 1982. [Computer program for afterloading radiation planning].. https://pubmed.ncbi.nlm.nih.gov/7146361/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A survey of physics and dosimetry practice of permanent prostate brachytherapy in the United States.

PURPOSE: To obtain data with regard to current physics and dosimetry practice in transperineal interstitial permanent prostate brachytherapy (TIPPB) in the U.S. by conducting a survey of institutions performing this procedure with the greatest frequency. METHODS AND MATERIALS: Seventy brachytherapists with the greatest volume of TIPPB cases in 1995 in the U.S. were surveyed. The four-page comprehensive questionnaire included questions on both clinical and physics and dosimetry practice. Individuals not responding initially were sent additional mailings and telephoned. Physics and dosimetry practice summary statistics are reported. Clinical practice data is reported separately. RESULTS: Thirty-five (50%) surveys were returned. Participants included 29 (83%) from the private sector and 6 (17%) from academic programs. Among responding clinicians, 125I (89%) is used with greater frequency than 103Pd (83%). Many use both (71%). Most brachytherapists perform preplans (86%), predominately employing ultrasound imaging (85%). Commercial treatment planning systems are used more frequently (75%) than in-house systems (25%). Preplans take 2.5 h (avg.) to perform and are most commonly performed by a physicist (69%). A wide range of apparent activities (mCi) is used for both 125I (0.16-1.00, avg. 0.41) and 103Pd (0.50-1.90, avg. 1.32). Of those assaying sources (71%), the range in number assayed (1 to all) and maximum accepted difference from vendor stated activity (2-20%) varies greatly. Most respondents feel that the manufacturers criteria for source activity are sufficiently stringent (88%); however, some report that vendors do not always meet their criteria (44%). Most postimplant dosimetry imaging occurs on day 1 (41%) and consists of conventional x-rays (83%), CT (63%), or both (46%). Postimplant dosimetry is usually performed by a physicist (72%), taking 2 h (avg.) to complete. Calculational formalisms and parameters vary substantially. At the time of the survey, few institutions have adopted AAPM TG-43 recommendations (21%). Only half (50%) of those not using TG-43 indicated an intent to do so in the future. Calculated doses at 1 cm from a single 1 mCi apparent activity source permanently implanted varied significantly. For 125I, doses calculated ranged from 13.08-40.00 Gy and for 103Pd, from 3.10 to 8.70 Gy. CONCLUSION: While several areas of current physics and dosimetry practice are consistent among institutions, treatment planning and dose calculation techniques vary considerably. These data demonstrate a relative lack of consensus with regard to these practices. Furthermore, the wide variety of calculational techniques and benchmark data lead to calculated doses which vary by clinically significant amounts. It is apparent that the lack of standardization with regard to treatment planning and dose calculation practice in TIPPB must be addressed prior to performing any meaningful comparison of clinical results between institutions.

Brachytherapy

Urinary incontinence in patients who have a TURP/TUIP following prostate brachytherapy.

PURPOSE: To determine urinary morbidity in patients who have transurethral resection of the prostate (TURP) after 125I brachytherapy. MATERIALS AND METHODS: A total of 109 patients with Stage T1-T2 prostatic carcinoma were treated with 125I implantation from 1991 through 1995. Ten patients underwent TURP/transurethral incision of the prostate (TUIP) after brachytherapy to relieve urinary obstruction refractory to nonsurgical management. RESULTS: Patients who developed refractory urinary retention had a slightly larger preimplant prostate volume than those who did not (62 vs. 54 ml; p = 0.16). Seven of the 10 patients developed some degree of permanent urinary incontinence following TURP/TUIP. Urinary incontinence was mild in three patients [Late Effects Normal Tissue Radiation Oncology Group (LENT) score = 1] and severe in four additional patients (LENT score = 3). There was no obvious relationship between the degree of incontinence and use of TURP vs. TUIP, amount of tissue resected, or time between brachytherapy and TURP/TUIP. In five patients for whom detailed urethral radiation dose information was available, the doses were higher than generally recommended. CONCLUSION: Permanent urinary incontinence is common in patients who require a TURP or TUIP after prostate brachytherapy. Its cause is apparently multifactorial and may include the degree of physical damage to the urinary sphincters and the radiation dose to the urethral region.

Brachytherapy