PubMed Health⌕ Search

PubMed · 7184147

X-ray microanalysis in dermatology.

Abstract

The current trends in X-ray microanalysis as applied to dermatology are described by reviewing papers which have made a significant contribution to the field. Under separate headings, the analysis of hair, nail and epidermis is reviewed with an emphasis on quantitative results. Our recent work on green hair has revealed a higher than normal copper content derived from copper-containing tap and pool water. In nail the sulfur content was shown to be evenly distributed throughout the nail plate and the calcium content to be too low to influence on the "hardness" of the nail. Our study of nails from cystic fibrosis patients showed that the Na, K, and C1 content increased, which is diagnostic for the disease, and that the Ca content could be used to monitor the preparation of nail samples for analysis. With the aid of X-ray microanalysis it has been possible for the first time to study the electrolyte composition of the different strata of epidermis by using freeze-fixed and freeze-dried cryosections. Only the basal stratum maintains a normal Na/K quotient and all cell layers above that one appear to have dysfunctional cell membranes, i.e. inadequate pumping of Na out of the cells. A subsequent study of the effects on normal epidermis by DNCB showed that after 6 hours post-treatment, abnormal Na, K and P levels appeared which differed from those seen in post-mortem changes of normal epidermis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Forslind. 1982. X-ray microanalysis in dermatology.. https://pubmed.ncbi.nlm.nih.gov/7184147/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper↗

Development of a new approach for microbial decontamination of water using modified Fenton's reaction.

Microbial decontamination of water was carried out using a novel radical generating system consisting of ion exchange resin, copper and hydrogen peroxide. The system was successful in reducing the microbial load in water by more than 99% in 15 min and is effective against all the microorganisms tested. The method was also successful in decontaminating the flood water obtained from Industrial Canal and 17th Street Canal in New Orleans. Decontamination is due to the formation of hydroxyl radicals, formed during the decomposition of hydrogen peroxide by the metal-polymer complex.

Copper↗