New Anger scintillation cameras with improved count rate capability.

Abstract

This paper proposes scintillation cameras which can handle input pulse rates beyond 1 Mcps with negligible as spatial resolution and energy resolution at low pulse rates. The cameras are based on the "variable sampling-time technique", in which phototube current pulses are first shortened in width and then selectively integrated by gated integrators followed by sample-and-hold circuits. The period of integration before sampling is not fixed but shortened by the arrival of the following pulse to keep a high pulse-pair time resolution. An approximate expression for the count rate characteristics has been derived, and its validity was confirmed by Monte Carlo simulation. The results indicates that the maximum observed count rate will reach 420-520 kcps with an energy window fraction of 0.5 for typical design parameters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E Tanaka, N Nohara, H Murayama. 1980. New Anger scintillation cameras with improved count rate capability.. https://doi.org/10.3769/radioisotopes.29.7_320

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Cerenkov counting.

When auditing research laboratories, health physics personnel are often alarmed to find liquid scintillation vials that only contain filters and no cocktail. They are then surprised when lab personnel state that they don't need cocktail to count their samples. While not frequently used by the health physicist, counting of samples by using Cerenkov radiation is valid and advantageous when correctly used.

Scintillation Counting↗

Use of a subcutaneous glucose sensor to detect decreases in glucose concentration prior to observation in blood.

The development of a hypoglycemic alarm system using a subcutaneous glucose sensor implies that a decrease in blood glucose is rapidly followed by a decrease in the signal generated by the sensor. In a first set of experiments the linearity and the kinetics of the response of sensors implanted in the subcutaneous tissue of normal rats were investigated during a progressive increase in plasma glucose concentration: the sensitivities determined between 5 and 10 mM and between 10 and 15 mM were not significantly different, and a 5-10 min delay in the sensor's response was observed. In a second set of experiments, performed in diabetic rats, the kinetics of the decrease in subcutaneous glucose concentration following insulin administration was monitored during a decrease in plasma glucose level, from 15 to 3 mmol/L. During the 20 first min following insulin administration, the sensor monitored glucose concentration in subcutaneous tissue with no lag time. Subsequently, the decrease in the estimation of subcutaneous glucose concentration preceded that of plasma glucose. This phenomenon was not observed when the same sensors were investigated in vitro during a similar decrease in glucose concentration and may be due to a mechanism occurring in vivo, such as the effect of insulin on glucose transfer from the interstitial space to the cells surrounding the sensor. It reinforces the interest of the use of implantable glucose sensors as a part of a hypoglycemic alarm.

Scintillation Counting↗