PubMed HealthSearch

PubMed · 7212605

Calibrant solutions for continuous-flow urate analysis: interference by formaldehyde.

Abstract

The use of formaldehyde to preserve aqueous urate calibration solutions has been recommended since 1913, but it interferes in some commonly used methods. At a pH below 8.5 formaldehyde affects the rate of dialysis of urate in Technicon AutoAnalyzer systems. This effect has been studied by variation of the pH at which dialysis takes place. The interference is attributed to the formation of pH-dependent addition products between uric acid and formaldehyde, which have been examined by thin-layer chromatography and mass spectrometry. Recovery experiments on protein-containing solutions show that a purely aqueous urate calibrant solution is satisfactory for use in AutoAnalyzer systems.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Beetham, P G Sanders. 1980. Calibrant solutions for continuous-flow urate analysis: interference by formaldehyde.. https://doi.org/10.1177/000456328001700609

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Potential of two-dimensional electrophoresis in routine identification of closely related durum wheat lines.

Four closely related durum wheat varieties were compared by computer-assisted analysis of two-dimensional electrophoretic maps of leaf proteins. A low inter-varietal polymorphism was revealed and seven reliable qualitatively varying proteins allowed rapid visual identification of genotypes. For numerous spots, presence/absence or quantitative variations were greatly affected by a batch effect. Several criteria that should be used to discard unreliable spots or gels a priori were reviewed. Nevertheless, it was shown that, provided that the experimental design allows the integration of the batch effect, screening for discriminant markers as well as computing distances based on protein quantity variations are possible and allow variety identification. Euclidean and Mahalanobis distances allowed variety discrimination and single gel classification with a minimum risk of error, not only by taking into account the quantitative variations in discriminant proteins selected by analysis of variance, but also by taking into account all reproducible spots. The possible applications of two-dimensional electrophoresis in variety identification are discussed.

Autoanalysis

Point-of-care glucose testing in the neonatal intensive care unit is facilitated by the use of the Ames Glucometer Elite electrochemical glucose meter.

OBJECTIVE: To evaluate the Ames Glucometer Elite glucose meter for use in point-of-care glucose testing in the neonatal intensive care unit. METHODS: An important part of our quality control program involves a weekly comparison of glucose values obtained with each of the seven Elite analyzers and the Beckman CX7 analyzer located in the central laboratory. Each "split" sample involves measurement of the glucose by using the Elite analyzer in a sample of blood obtained from a heel stick at the bedside, followed by bleeding ("milking") 150 to 200 microl (4 to 5 drops) of blood into a heparinized microcontainer. This process should take no longer than 1 to 2 minutes, whereupon the microcontainer is placed on ice and sent to the laboratory. The values obtained were compared by regression analysis. Imprecision of the Elite meter was estimated at four levels of blood glucose concentration and on a normal-level quality control sample used for a period of 4 months. RESULTS: Regression analysis between the glucose values obtained on the Elite meter and the CX7 meter revealed r = 0.93, p less than 0.0001, n = 188, Sy/x = 0.59 mmol/L, intercept = 0.47 +/- 0.14 mmol/L (1 SEM), and slope = 0.91 +/- 0.028 (1 SEM). When we switched to on-ice delivery of split samples to reduce metabolic activity during transport of the specimens to the laboratory, scatter about the regression line was decreased and the Sy/x was reduced to 0.45 mmol/L. Before the on-ice delivery of split samples, 24% of the Elite analyzer's results differed from those of the CX7 analyzer by more than 15%, whereas only 8% differed from those of the CX7 meter by more than 15% after on-ice delivery of split samples. Of 30 samples read as "Lo" by the Elite meter, 29 were less than 2.2 mmol/L on the CX7 meter, whereas only 1 was 2.2 mmol/L. The coefficients of variation taken as a measure of imprecision were less than 5% for the normal-level aqueous control and less than 5% for four heel-stick blood glucose levels. CONCLUSIONS: The Ames Glucometer Elite analyzer can be used with confidence in measuring heel-stick blood glucose concentrations at the bedside in the neonatal intensive care unit. Hypoglycemic blood samples are reliably detected. As with adults, meticulous technique should be followed to prevent filling defects, and all split samples should be analyzed promptly on the CX7 analyzer, with delivery to the laboratory on ice. Unlike previous generations of glucometers, the Elite meter has been well accepted by the neonatal nursing staff.

Autoanalysis

Assessment of an automated immunoassay based on kinetic interaction of microparticles in solution for determination of opiates and cocaine metabolite in urine.

A recently introduced automated immunoassay which is based on kinetic interaction of microparticles in solution (Roche ONLINE), was evaluated for the detection of cocaine metabolite benzoylecgonine (BE) and opiates in human urine. Cross-reactivity for the opiates morphine (100%), codeine (88%), 6-monoacetylmorphine (88%), and morphine 3-glucuronide (72%) was assessed. Analytical recovery evaluated on blank urines spiked with 0, 250, 300, 350, and 500 micrograms/L of morphine and BE (n = 10), varied from 85.2 to 100.2% for opiates and from 81.4 to 93.1% for the cocaine metabolite. The within-day precision ranged from 1.4 to 4.7% for morphine and from 4.2 to 4.8% for BE. The repeatability of the standards over 1 month was 1.0-3.3% for opiates and 1.7-5.1% for BE, and thus allowing measurements to continue over 30 days without re-calibration. This method compared favourably with the SYVA EMIT d.a.u system and gas chromatography/mass spectroscopy (GC/MS) methods.

Autoanalysis