PubMed · 7303070

Quantitative carotid phonoangiography.

Abstract

One hundred and sixteen carotid artery bruits were assessed using quantitative phonoangiography (spectral bruit analysis - SBA). This technique uses the averaged break frequency of the bruit to calculate the diameter of he residual lumen at the site of stenosis. Biplanar contrast arteriography was performed on 43 (37%) of the sides. All 116 sides were also evaluated with an ultrasonic Duplex scanner. Ten (8.6%) bruits could not be analyzed by the SBA, leaving 106 sides in which the residual lumen diameter could be estimated. The diameter of the vessel at the site of stenosis estimated by SBA and arteriography were compared and found to agree within 1 mm of each other in 85% of patients. A linear relationship was demonstrated between absolute lumen diameter and percent stenosis as measured from the arteriograms, but we were unable to correlate the absolute diameter of hte residual lumen as assessed by arteriography or SBA with the assessment of the degree of the stenosis derived from spectral analysis of the pulsed Doppler signal. The significance of these findings is discussed with relevance to the clinical application of spectral bruit analysis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Knox, P Breslau, D E Strandness. Quantitative carotid phonoangiography.. https://doi.org/10.1161/01.str.12.6.798

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Transmission of lung sounds through light clothing.

BACKGROUND: Doctors are exhorted to always place the stethoscope directly on the skin and never to auscultate through clothing. Nevertheless, casual observation reveals that doctors and even pulmonologists often violate this principle. OBJECTIVES: This study was designed to evaluate the sensitivity of two common stethoscopes when used through clothing. METHODS: Littmann Classic and Littmann Master Cardiology stethoscopes were studied under conditions of light (60-100 g), medium (240 g) and heavy (555 g) force when placed on a lung sound test platform with one or two layers of cloth (T-shirt material and flannel) interposed between the stethoscope and the test surface. The test platform was designed to mimic the acoustic and mechanical properties of the chest wall and was driven by amplified white noise. The recorded amplitude spectra were compared over a range of 150-1,000 Hz. RESULTS: Compared to the sensitivity on a bare test platform surface, either fabric in single or double layers attenuated the sounds by a mean of 5-18 dB under light pressure. This attenuation was nearly abolished by the addition of either medium or heavy force on the stethoscope head. CONCLUSIONS: The deleterious effect of one or two layers of indoor clothing on lung sounds acquired through a stethoscope can be negated by force on the stethoscope head making effective auscultation possible. Nevertheless, auscultation through clothing remains problematic due to the hindrance to inspection and percussion and the risk of acoustic artifacts caused by clothing.

Auscultation↗

A huge obstructive myxoma located in the right heart without causing any symptom.

Cardiac myxoma is unusual and mostly located in left atrium. Although it is a benign tumor of the heart, it may cause life-threatening cardiac problems like valvular obstruction, systemic or pulmonary massive embolism, infection, arrhythmia, malignance. We report a huge cardiac myxoma originated from right atrium. It was moving between right atrium and ventricle without any symptoms.

Auscultation↗