Tissue pH electrodes for clinical applications.

Abstract

The reduction of peripheral blood flow, which occurs during shock or in patients with occlusive arterial disease of the lower limb is accompanied by an increase in hydrogen ion activity in tissue cells. If this change could be measured, it could possibly be used as an indicator of tissue perfusion in such patients. Investigations have been carried out into various pH microelectrode designs in order to construct one which could be used clinically to measure extracellular pH changes in skin. Experiments with antimony and externally insulated glass micro-electrodes demonstrated that these were unsatisfactory for the purpose. The successful design was insulated internally by means of a glass to glass fuse. It was robust, stable, sensitive and had a fast response time. Use of the electrode in normal volunteers produced reproducible skin pH values and demonstrated the feasibility of the system. Preliminary results using the micro-electrodes in patients indicate their possible application to the assessment of peripheral vascular disease, and to the monitoring of patients under intensive care.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D K Harrison, W F Walker. 1980. Tissue pH electrodes for clinical applications.. https://doi.org/10.3109/03091908009161079

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrochemical treatment of paper mill wastewater using three-dimensional electrodes with Ti/Co/SnO2-Sb2O5 anode.

The properties of the interlayer and outer layer of Ti/Co/SnO2-Sb2O5 electrode were studied, and the electrochemical behavior was examined as well. As a result of unsatisfactory treatment using Ti/Co/SnO2-Sb2O5 electrode, electrochemical disposal of paper mill wastewater employing three-dimensional electrodes, combining active carbon granules serving as packed bed particle electrodes, with Ti/Co/SnO2-Sb2O5 anode, was performed. The outcome demonstrates that efficient degradation was achieved. The residual dimensionless chemical oxygen demand (COD) concentration reached 0.137, and color removal 75% applying 167 mA cm(-2) current density at pH 11 and 15 g l(-1) NaCl. The instant current efficiency, energy cost, electrochemical oxidation index (EOI) and kinetic constant of the reaction were calculated. At the same time, the influence of pH and current density on COD abatement and decolorization was also investigated, respectively.

Antimony↗

Comparison of antimony behavior with that of arsenic under various soil redox conditions.

The oxidation states and host phases of Sb and As in soil samples of mine tailing (Ichinokawa mine, Ehime, Japan) and in laboratory soil-water systems were determined by X-ray absorption fine structure (XAFS) spectroscopy. HPLC-ICP-MS was used for speciation of Sb and As in soil water. In the Ichinokawa soil water system, Sb was present exclusively as the oxidized form, Sb(V), over a wide redox range (from Eh = 360 to -140 mV, pH 8), while As was present as a mixture of As(III) and As(V). This finding was confirmed in the laboratory experiments. These results suggest that Sb(V) is a very stable form in the environment and that Sb is oxidized at more negative Eh than As. Combining the results of Fe and Mn XAFS analyses and a positive correlation among Sb, As, and Fe abundances in the soil, the host phases of Sb and As in soil were Fe(III) hydroxide. XAFS analyses of Sb and As are also consistent with this finding. Under reducing conditions, the concentration of As in the soil water increased whereas that of Sb decreased in both the Ichinokawa and laboratory systems. This suggests that this contrasting behavior is controlled mainly by the different redox properties of Sb and As.

Antimony↗