PubMed Health⌕ Search

PubMed · 7377263

Scleral buckling without thermal adhesion.

Abstract

One hundred seventy-five consecutive and unselected patients with retinal detachment were treated with a scleral buckling procedure without inducing a thermal adhesion. In 143 (82%) of these patients reattachment was successful after one operation. In 32 patients (18%) reattachment was not initially successful. These failures resulted from buckle malposition, periretinal proliferation, new or missed breaks, and the inability to close giant tears. Fifteen of the 32 reattached after subsequent scleral buckling without thermal adhesion. Final success was achieved, therefore, in 158 (90%) of the original group of 175 cases. We concluded that a chorioretinal scar might have prevented initial failure only in those cases of buckle malposition. The high incidence (17, [10%]) of periretinal proliferation, accounting for all of our final failures, did not concur with or support previous impressions indicating a causal relationship between thermal treatment and proliferative complications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C L Fetkenhour, T L Hauch. 1980. Scleral buckling without thermal adhesion.. https://doi.org/10.1016/0002-9394(80)90285-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Understanding submucosal electrosurgery for the treatment of nasal turbinate enlargement.

The surgical management of inferior turbinate enlargement is controversial. Submucosal electrosurgical techniques for turbinate reduction include conventional diathermy, radiofrequency tissue reduction and coblation. All electrosurgical techniques use radiofrequency electricity to damage turbinate tissue but differ in the control and delivery of energy. This review will examine the history of submucosal electrosurgery and clarify the various techniques. This review will also examine the evidence for the efficacy and safety of electrosurgery for the treatment of nasal turbinate enlargement, and will make a case that no progress will be made in clinical trials on the safety and efficacy unless there is standardisation of equipment and techniques in nasal electrosurgery.

Diathermy↗

Measurement of the specific heat capacity of liver phantom.

Phantoms are often used to simulate tissue during the development, testing and calibration of medical devices. In order to infer the specific absorption rate (SAR) and resistive heating in phantoms from temperature measurements, the specific heat capacity and density of the phantom are needed. Stauffer et al (2003 Int. J. Hyperth. 19 89-101) developed several phantoms that mimic dielectric properties of liver tissue at 915 MHz. However, thermal properties of the phantoms were not presented. We have measured specific heat capacities and densities for these phantoms. We also present dielectric properties for these phantoms measured from 0.7 to 20 GHz, including 2.45 GHz--a commonly used frequency for microwave hyperthermia and ablation.

Diathermy↗