PubMed Health⌕ Search

PubMed · 7469607

[The use of microcomputers in the processing of complex hemodynamic data].

Abstract

The use of a low-cost microcomputer in the clinical study of left ventricular diastolic function is described. Both left ventricular filling and compliance were studied by means of the simultaneous recording of left ventricular pressure and an echocardiogram displaying ventricular dimensions. A program was written to calculate ventricular volume every 40 msec and a volume-time diagram was obtained. The raw curve was smoothed with a second degree polinomial. The rate of change of ventricular volume (dV/dt) was obtained. Simultaneous left ventricular volume and pressure were plotted. The diastolic, exponential portion of the pressure-volume loop was used to calculate an index of ventricular stiffness at zero volume. It is concluded that a simple microcomputer, when conveniently programed, is able to perform the time-consuming mathematical operations involved in the clinical assessment of left ventricular diastolic function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Rivera, E Meaney, M Briseño, E Suárez, E Llano, R Romero, A García, R González. [The use of microcomputers in the processing of complex hemodynamic data].. https://pubmed.ncbi.nlm.nih.gov/7469607/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Five-dimensional MRI incorporating simultaneous resolution of cardiac and respiratory phases for volumetric imaging.

PURPOSE: To develop a new volumetric imaging method resolved over both the cardiac and respiratory cycles, to enable future physiological and pathophysiological studies of respiratory-related cardiac motion. MATERIALS AND METHODS: An acquisition scheme is proposed whereby the k-space acquisition order is controlled in real-time by the current cardiac and respiratory phases. To reduce eddy-current effects induced by sudden jumps in k-space, the acquisition order is further optimized by the use of a Hilbert curve trajectory in the k(y)-k(z) plane. A complete three-dimensional (3D) k-space is acquired for all combinations of cardiac and respiratory phases, yielding a five-dimensional (5D) data set after retrospective reconstruction. RESULTS: Left (LV) and right ventricular (RV) wall excursion was measured in a healthy volunteer. Diastolic LV diameter was shown to increase during expiration and decrease during inspiration, as expected from previous echocardiography studies. The LV volume was estimated for all cardiac and respiratory phases with the use of a fully 3D segmentation tool. The results confirmed that the diastolic LV volume increased during expiration and decreased during inspiration. CONCLUSION: With its ability to measure motion anywhere in the heart, the described technique provides a promising approach for in-depth description of interventricular coupling, including 3D ventricular volumes, during both the cardiac and respiratory cycles.

Cardiac Volume↗

Utility of 256-slice cone beam tomography for real four-dimensional volumetric analysis without electrocardiogram gated acquisition.

PURPOSE: Current ECG-gated multislice CT can reveal any cardiac phase data, including four-dimensional (4D) images, but cannot acquire the whole heart in one scanning, and arrhythmias impair the quality of the images. We used a prototype 256-slice cone beam CT (Athena, Sony Toshiba), with which the whole heart can be acquired in one scanning. MATERIALS AND METHODS: A pulsating device with contrast material (300 mgI/dl) diluted 10x with saline was moved at 5, 40, 60, 70, and 90 to-and-fro movements/min. Non-ECG-gated 256-slice cone beam CT with 256 x 0.5 mm slice thickness was performed during one to-and-fro motion at each rate. After acquisition, each to-and-fro motion was divided into 20 frames, and each volume was measured and volumetric curves were constructed. RESULTS: Even without ECG-gated acquisition, the configuration of the pulsating device at any rate continued to the through plane without any gaps, and the 4D movie of the pulsating device could be observed at any rate except 60 movements/min. Volumes of end-diastole (ED) and end-systole (ES), and ejection fraction (EF) at static state were 81.7, 17.5 ml, and 79% respectively. ED volumes were 81.7, 81.7, 70.3, 63.7, 68.3 and 65.9 ml, ES volumes were 17.5, 30.9, 39.8, 62.7, 55.0 and 43.2 ml, and EF was 79, 62, 43, 2, 19 and 34% at 0, 5, 40, 60, 70, and 90 to-and-fro movements/min, respectively. The ratios of ED volume, using the static state as the reference, were 100, 86, 78, 84 and 81%, those of ES volume were 177, 227, 358, 314 and 247%, and those of EF were 78, 54, 3, 24 and 43% at 5, 40, 60, 70, and 90 to-and-fro movements/min, respectively. From the configuration of volumetric curves, only 5/min could be evaluated. At 60 movements/min, the same device images without any motion were observed in 4D images during one to-and-fro motion. This may be because one to-and-fro time and one scanning time were the same (1 s). CONCLUSION: Even without ECG-gated acquisition, this new 256-slice cone beam CT achieved real 4D analysis of the pulsating device. The ED volume and the configuration of volumetric curve could only be evaluated up to 5 movements/min, but because of poor spatial resolution (1 s/rotation), even at 5 movements/min ES volume tended to be overestimated. As a result, EF tended to be underestimated, which may be improved in the next generation (0.5 s/rotation).

Cardiac Volume↗