[Agents preventing decrease in ultrafiltration in a rat model with peritoneal hyperpermeability].

Abstract

Ultrafiltration failure has been one of the major causes of drop out from CAPD treatment. The present study was designed to develop an ultrafiltration failure model in the rat and to assess whether various agents could prevent a decrease in ultrafiltration capacity in this rat model. Peritoneal hyperpermeability was induced by repeated intraperitoneal injection of 15 ml of 4.25% dextrose dialysate for 7 days. Some of the rats received agents, such as phosphatidylcholine, chondroitin sulfate, siliac acid, heparan sulfate, keratan sulfate, sodium sulfate, sodium phosphate, and heparin sodium, simultaneously administered with 4.25 % dextrose dialysate for the same duration. Ultrafiltration volume, D4/D0 ratio of glucose and peritoneal net fluid absorption were evaluated by 4-hour dwelling of 30 ml of 2.5% dextrose dialysate. Sodium phosphate and heparan sulfate prevented peritoneal hyperpermeability due to repeated injection of hypertonic dialysate. Sodium phosphate, sodium sulfate, heparin and heparan sulfate suppressed peritoneal net fluid absorption, resulting in an increase in ultrafiltration. These findings may be applicable to CAPD patients with ultrafiltration loss.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Suyama, K Kumano, T Sasaki. 1995. [Agents preventing decrease in ultrafiltration in a rat model with peritoneal hyperpermeability].. https://pubmed.ncbi.nlm.nih.gov/7474515/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pharmacokinetics of an oral solution of the microemulsion formulation of cyclosporine in maintenance pediatric liver transplant recipients.

BACKGROUND: A comparison of the oral bioavailability of cyclosporine from the original formulation (CsA) and from the new formulation, cyclosporine for microemulsion (CsA-ME), was made in pediatric maintenance liver transplant patients within two age groups (group 1, ages 1-5 years; group 2, ages 6-17 years) in an open-label, multicenter, randomized crossover trial. All patients were at least 6 months past transplantation and were receiving CsA maintenance therapy. METHODS: In study period 1 (days 1 through 14), patients were administered either CsA or CsA-ME at the same b.i.d. dosage as their maintenance therapy. Upon entry into period 2 (days 15 through 28), patients were converted to the alternate formulation at a 1:1 mg dose ratio. On day 29, all patients returned to the CsA treatment administered at study entry, with follow-up on day 35. Dosage adjustments were not allowed with either CsA or CsA-ME. Twelve-hour pharmacokinetic profiling was performed at the end of periods 1 and 2. RESULTS: Both the mean area under the concentration-versus-time curve and the mean maximum blood concentration of cyclosporine-both normalized for dose-were significantly increased: by 66% and 109%, respectively, in patients receiving CsA-ME compared with those receiving CsA in group 1 and by 39% and 75%, respectively, in group 2. During this study, liver function remained stable, and serum creatinine and blood pressure did not differ significantly between treatment groups. CONCLUSIONS: This study shows increased bioavailability in all patients converted to CsA-ME, with the greatest increase seen in patients with the lowest initial cyclosporine bioavailability. The tolerability was similar between the two formulations during this study.

Absorption

The urinary excretion of solvents and gases for the biological monitoring of occupational exposure: a review.

'In the field' application of the measurement of urinary excretion of unmodified solvent for the biological monitoring of exposed workers has been investigated in many recent papers. The results obtained for several solvents are reviewed. The values of correlation coefficients (r) and regression lines obtained for benzene, toluene, xylene, styrene, n-hexane, cyclohexane, 2- and 3-methylpentane, methyl chloride, tetrachloroethylene, carbon tetrachloride, methyl chloroform, p-dichlorobenzene, nitrous oxide, halothane, isoflurane, enflurane, acetone, methyl ethyl ketone and methyl isobutyl ketone are presented. The correlations observed were generally good: r values range from 0.50-0.97, and the majority are between 0.84 and 0.90. The regression lines reported for the same solvent in different studies present some variability: this is possibly due to an inadequate control of factors influencing the relationship between external dose and absorption, such as differences in body burden, work load, individual characteristics, etc. These factors are discussed. As a whole, results reported in the literature show that measuring of urinary excretion of unmodified solvents provides a highly sensitive and specific exposure index, and can also be applied for the biological monitoring of occupational exposure to low levels of solvents or to solvent mixtures. Nevertheless, for an adequate assessment of biological limit values, further studies evaluating the reproducibility of regression lines are needed, given that the aspects influencing the correlation between external dose and urinary excretion are fully controlled. Another crucial aspect is the correlation with early effects: even though this has yet to be evaluated for several solvents, for others such as styrene and perchloroethylene a good correlation was obtained, further supporting the usefulness of the measurement of urinary excretion of solvent for the biological monitoring of occupational exposure.

Absorption

A novel device for capturing breath samples for solvent analysis.

We have developed a novel breath sampling device suitable for capturing a portion of end-tidal air. This breath sample is then transferred onto a Perkin Elmer automated thermal desorption (ATD) sampling tube which is subsequently analysed by ATD-gas chromatography-mass spectrometry (GCMS). The breath sampler has been evaluated in the laboratory, in brief field trials and in human volunteer studies. The method is sensitive with a typical detection limit of 1 nmol/l and reproducible with an overall coefficient of variation between 5% and 15% for collection and analysis of breath samples from volunteers. The field trials used the sampler to assess exposure to solvents in several industries including the shoe manufacturing industry, the inks and coatings industry and at dry cleaning establishments. The sampler was found easy to use and reliable. Solvents detected include ethyl acetate (6.4-25.5 nmol/l), propan-2-ol (3.4-39.3 nmol/l), 2-butanone (0-6.6 nmol/l) and tetrachloroethene (0-557 nmol/l). The breath sampler was also used to monitor the elimination of solvents in breath from human volunteers after exposure chamber studies. More than 500 breath samples have been analysed from 24 volunteers in exposures to 10 different solvents (toluene, trimethyl benzene, tetrachloroethene, tetrahydrofuran, acetone, propan-2-ol, xylene, 2-butanone, 1-methoxy-2-propanol and n-hexane). The breath sampler allowed the rapid and non-invasive collection of data on elimination of solvents.

Absorption