Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.

Abstract

Head-scatter factors of symmetric square and rectangular fields (field center on the central beam axis) defined by the upper (Y) and lower (X) jaws for 6 and 15 MV photon beams from 2300CD and 600C accelerators (Varian Associates, Inc., Palo Alto, CA) were measured, as well as those for fields shaped by the Y jaws and the multileaf collimator (MLC) of the 2300CD. For rectangular fields, the head-scatter factor for the field (x = a and y = b) was different from that for the field (y = a and x = b). This difference was 2% -3% for fields defined by conventional collimators when [formula, see text] was large, and became 4%-5% when the MLC and YT jaws were used to shape the fields with the X jaws retracted. In order to calculate values for head-scatter factors of rectangular fields accurately using an equivalent square formalism, the side of the equivalent square should be obtained with different weights for lower and upper jaws, as proposed by Vadash and Bjärngard [Med. Phys. 20, 733-734 (1993)]. Our measurements demonstrate that the relative weight (G) of upper and lower jaws is strongly dependent on their distances from the x-ray source, while the beam energy has little effect on the value of G. We further show that G can be calculated simply from these distances. An analytical representation for head-scatter factors of square and rectangular fields is also developed in this paper. The quality of this representation was judged by the root-mean-square (rms) deviation from measured head-scatter factors, which ranged from 0.11%-0.27%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M K Yu, B Murray, R Sloboda. 1995. Parametrization of head-scatter factors for rectangular photon fields using an equivalent square formalism.. https://doi.org/10.1118/1.597617

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multidetector CT and dentascan software: dosimetric evaluation and technique improvement.

PURPOSE: The development of new operative techniques in oral and maxillofacial surgery within the last few years has led to an increasing demand for Dentascan examination, also in paediatric patients. It is necessary to modify acquisition parameters to reduce the absorbed dose. The aim of this study was to define a Dentascan protocol in which a reduced X-ray dose could be used. MATERIALS AND METHODS: Dosimeters were applied to the eyes, mouth, parotid glands, thyroid and back of the neck of an anthropomorphic Plexiglas phantom that underwent multidetector computed tomography (MDCT) Dentascan examinations. Both 120kV and 80 kV were used to study the mandibular and maxillary arches. RESULTS: Examinations obtained with the 80 kV protocol showed a ten-fold reduction in the absorbed dose, without affecting image quality. CONCLUSIONS: We suggest a Dentascan protocol that reduces the X-ray dose administered to the patient while ensuring the same high diagnostic accuracy.

Head↗