PubMed · 7517958
Evaluation of a safe sputum processing method for detecting tuberculosis.
Abstract
AIMS: To evaluate a safe sputum processing method for detection of tuberculosis in developing countries. METHODS: A sample processing method was developed in which acid fast bacilli were killed with 1% sodium hypochlorite and concentrated by flotation on a layer of xylene before staining by the Ziehl Neelsen or auramine O methods. RESULTS: Best results were obtained by auramine O staining after flotation. Staining by the Ziehl Neelsen method after flotation gave better results than direct Ziehl Neelsen staining without flotation. CONCLUSIONS: The flotation method with Ziehl Neelsen staining offers advantages for smear preparation in the tuberculosis control programmes of developing countries.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A Rattan, K Kishore, S Singh, M Jaber, I Xess, R Kumar. 1994. Evaluation of a safe sputum processing method for detecting tuberculosis.. https://doi.org/10.1136/jcp.47.5.411