PubMed HealthSearch

PubMed · 7634356

[Thoracic electric bioimpedance. Basic principles and physiologic relationships].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Sramek. [Thoracic electric bioimpedance. Basic principles and physiologic relationships].. https://pubmed.ncbi.nlm.nih.gov/7634356/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Improvement of cardiac imaging in electrical impedance tomography by means of a new electrode configuration.

Until now, electrical impedance tomography (EIT) has been used for cardiac imaging with the electrodes attached transversally at the level of the fourth intercostal space at the anterior side. However, the results obtained with this electrode configuration have been disappointing. The aim of the present study was to improve the measurement design of EIT for cardiac imaging. Therefore, magnetic resonance imaging (MRI) scans were analysed in two healthy subjects to determine the optimum anatomical plane in which atria and ventricles are clearly visually separated. From these findings, we proposed a new oblique plane at the level of the ictus cordis anteriorly and 10 cm higher posteriorly. EIT pictures obtained in the oblique plane revealed a better visual separation between the ventricles and atria than with the electrodes attached in the transverse plane. Comparison between volume changes measured by means of MRI and impedance changes in different regions of interest measured with EIT were performed with the electrodes in the proposed oblique plane. Ventricular and atrial volume changes measured by MRI show the same pattern as do impedance changes measured by EIT. Furthermore, we assessed the reproducibility and validity of the oblique electrode configuration in ten healthy mate volunteers during rest and during exercise compared with the currently used transverse electrode configuration. The reproducibility coefficient assessed from repeated measurements with the electrodes attached in the oblique plane was 0.98 at rest and 0.85 during exercise. For the transverse plane the reproducibility coefficient was 0.96 at rest and 0.66 during exercise. The well-known increase in stroke volume during exercise is 40% in healthy subjects. The increase in impedance change during exercise compared with rest was 34 +/- 13% (20-59%) for the oblique plane and 68 +/- 57% (13-140%) for the transverse plane. From these results we infer that the stroke volume is assessed more accurately by using the oblique plane. From these findings, we conclude that the oblique plane improved the cardiac measurements, because (i) a better spatial separation of the heart compartments is obtained, (ii) the results are more reliable and (iii) measurements during exercise are more accurate with the electrodes attached in an oblique plane.

Cardiography, Impedance

The safety of digital mobile cellular telephones with minute ventilation rate adaptive pacemakers.

In vitro tests suggest that rate adaptive pacemakers using changes in transthoracic impedance to vary pacing rate may be affected by digital mobile telephones. Electromagnetic fields generated by digital mobile telephones (Global System for Mobile [GSM]) represent a potential source of electromagnetic interference (EMI) for the Telectronics META rate adaptive pacemakers, which use transthoracic impedance as a sensor to determine changes in minute ventilation. Sixteen implanted Telectronics META pulse generators were exposed to 25-W simulated GSM transmissions (900-MHz carrier pulsed at 2, 8, and 217 Hz with a pulse width of 0.6 ms) and the antenna of a 2-W digital mobile telephone (900-MHz, 217-Hz pulse, 0.6-ms pulse width). The 12 dual and four single chamber devices were programmed to maximum sensitivity and assessed in unipolar and bipolar settings and rate adaptive and nonrate adaptive modes. In all cases of EMI, testing was repeated at lower, more routinely set bipolar sensitivity levels. At maximum sensitivity, 11 of 16 devices displayed no evidence of EMI. Brief ventricular triggering occurred in 2, a brief pause in 1, a combination of both in 1, and a brief episode of pacemaker-mediated tachycardia in 1. With pulse generators programmed to more routine sensitivities, only one device displayed rare single beat ventricular triggering. No changes in minute ventilation rate adaptive pacing were observed. At maximum unipolar sensitivities, the META series of rate adaptive pacemakers are resistant to clinically important EMI from digital mobile telephones. Set at routine sensitivities, these devices perform reliably in the presence of digital mobile telephones.

Cardiography, Impedance