PubMed Health⌕ Search

PubMed · 7674887

MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy.

Abstract

We present a method to correct the geometric distortion caused by field inhomogeneity in MR images of patients wearing MR-compatible stereotaxic frames. Our previously published distortion correction method derives patient-dependent error maps by computing the phase-difference of 3D images acquired at different TEs. The time difference (delta TE = 4.9 ms at 1.5 T) is chosen such that the water and fat signals are in phase. However, delta TE is long enough to permit phase wraps in the difference images for frequency offsets greater than 205 Hz. Phase unwrapping techniques resolve these only for connected structures; therefore, the phase difference for fiducial rods may be off by multiples of 2 pi relative to the head. We remove this uncertainty by using an additional single 2D phase-different image with delta TE = 1 ms (during which time no phase-wraps are typically expected) to determine the correct multiple of 2 pi for each rod. We tested our method in a cadaver and in a patient using CT as the gold standard. Targets in the frame coordinates were chosen from CT and compared with their locations in MR. Localizing errors using MR compared with CT were as large as 3.7 mm before correction and were reduced to less than 1.11 mm after correction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T S Sumanaweera, G H Glover, P F Hemler, P A van den Elsen, D Martin, J R Adler, S Napel. 1995. MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy.. https://doi.org/10.1002/mrm.1910340116

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗