Electronic article surveillance: a possible danger for pacemaker patients.

Abstract

In order to evaluate if antitheft devices commonly designed as electronic article surveillance (EAS) systems can be dangerous for pacemaker patients, in vitro and in vivo studies were made in close cooperation between a pacemaker center and an EAS designer. Three types of EAS radiation including radiofrequency, magnetic, and pulsed electromagnetic fields were applied to various pacemakers. The in vitro study consisted of exposing to the EAS fields 28 pacemakers connected to unipolar leads. Radiofrequency fields and pulsed electromagnetic fields evoked minor effects and no prolonged inhibitions. When exposed to magnetic fields, most of the pacemakers switched to "fixed rate" pacing, but inhibitions were observed in 13 pacemakers exposed to 300 Hz, and in 14 pacemakers exposed to a 10-kHz magnetic field when they were moved at cardiac frequencies within the fields. The in vivo study was made on 32 volunteers treated by 26 different pacemakers: 22 single chamber and ten dual chamber. All patients had been monitored in the pacemaker clinic and pacemakers were working well. Radiofrequency and pulsed electromagnetic fields did not affect the pacemaker function. Magnetic interference evoked prolonged inhibition of seven out of the ten dual chamber pacemakers, causing brief asystole in patients being continually paced. None of the dual chamber pacemakers incorporated "safety stimulation intervals" after ventricular blanking. The EAS artifact was sensed after the ventricular blanking causing a cross-talk ECG pattern. No reprogramming was induced by the electromagnetic fields. This experience demonstrates that certain EAS may be dangerous for pacemaker patients. Following this cooperative study a pacemaker safe EAS circuit delivering short bursts of magnetic fields has been designed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Dodinot, J P Godenir, A B Costa. 1993. Electronic article surveillance: a possible danger for pacemaker patients.. https://doi.org/10.1111/j.1540-8159.1993.tb01534.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗