Surface denaturation at solid-void interface--a possible pathway by which opalescent particulates form during the storage of lyophilized tissue-type plasminogen activator at high temperatures.

Abstract

During protein lyophilization, it is common practice to complete the freezing step as fast as possible in order to avoid protein denaturation, as well as to obtain a final product of uniform quality. We report a contradictory observation made during lyophilization of recombinant tissue-type plasminogen activator (t-PA) formulated in arginine. Fast cooling during lyophilization resulted in a lyophilized product that yielded more opalescent particulates upon long term storage at 50 degrees C, under a 150 mTorr nitrogen seal gas environment. Fast cooling also resulted in a lyophilized cake with a large internal surface area. Studies on lyophilized products containing 1% (w/w) residual moisture and varying cake surface areas (0.22-1.78 m2/gm) revealed that all lyophilized cakes were in an amorphous state with similar glass transition temperatures (103-105 degrees C). However, during storage the rate of opalescent particulate formation in the lyophilized product (as determined by UV optical density measurement in the 360 to 340 nm range for the reconstituted solution) was proportional to the cake surface area. We suggest that this is a surface-related phenomenon in which the protein at the solid-void interface of the lyophilized cake denatures during storage at elevated temperatures. Irreversible denaturation at the ice-liquid interface during freezing in lyophilization is unlikely to occur, since repeated freezing/thawing did not show any adverse effect on the protein. Infrared spectroscopic analysis could not determine whether protein, upon lyophilization, at the solid-void interface would still be in a native form.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C C Hsu, H M Nguyen, D A Yeung, D A Brooks, G S Koe, T A Bewley, R Pearlman. 1995. Surface denaturation at solid-void interface--a possible pathway by which opalescent particulates form during the storage of lyophilized tissue-type plasminogen activator at high temperatures.. https://doi.org/10.1023/a%3A1016270103863

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The relevance of the amorphous state to pharmaceutical dosage forms: glassy drugs and freeze dried systems.

Many pharmaceuticals, either by accident or design, may exist in a total or partially amorphous state. Consequently, it is essential to have an understanding of the physico-chemical principles underpinning the behaviour of such systems. In this discussion, the nature of the glassy state will be described, with particular emphasis on the molecular processes associated with glass transitional behaviour and the use of thermal methods for characterising the glass transition temperature, Tg. The practicalities of such measurements, the significance of the accompanying relaxation endotherm and plasticization effects are considered. The advantages and difficulties associated with the use of amorphous drugs will be outlined, with discussion given regarding the problems associated with physical and chemical stability. Finally, the principles of freeze drying will be described, including discussion of the relevance of glass transitional behaviour to product stability.

Calorimetry, Differential Scanning

Thermal analysis of hydroxypropylmethylcellulose and methylcellulose: powders, gels and matrix tablets.

This review focuses on the thermal analysis of hydroxypropylmethylcellulose (HPMC) and methylcellulose. Differential scanning calorimetry (DSC) of their powders is used to determine temperatures of moisture loss (in conjunction with thermogravimetric analysis) and glass transition temperatures. However, sample preparation and encapsulation affect the values obtained. The interaction of these cellulose ethers with water is evaluated by DSC. Water is added to the powder directly in DSC pans or preformed gels can be evaluated. Data quality depends on previous thermal history but estimates of the quantity of water bound to the polymers may be made. Water uptake by cellulose ethers may be evaluated by the use of polymeric wafers and by following loss of free water, over a series of timed curves, into wafers in contact with water. Cloud points, which assess the reduction of polymer solubility with increase of temperature, may be assessed spectrophotometrically. DSC and rheometric studies are used to follow thermogelation, a process involving hydrophobic interaction between partly hydrated polymeric chains. The advantages and disadvantages of the various methodologies are highlighted.

Calorimetry, Differential Scanning

pH-dependent thermal transitions of lentil lectin.

The thermal stability of lentil lectin in the 5.0-10.0 pH range was studied by high-sensitivity differential scanning calorimetry and infrared spectroscopy. The thermally induced transitions for protein were irreversible and strongly dependent upon the scan rate at all pH values, suggesting that the denaturation is under kinetic control. It is shown that process of lentil lectin denaturation can be interpreted with sufficient accuracy in terms of the simple kinetic scheme, N-->D, where k is a first-order kinetic constant that changes with temperature, as given by the Arrhenius equation, N is the native state, and D is the denatured state. On the basis of this model, the parameters of the Arrhenius equation were calculated.

Calorimetry, Differential Scanning