The practical management of artifact in computerised physiological data.

Abstract

Computerised physiological data contains artifact that needs to be identified and possibly removed. Whilst computers may eventually satisfactorily perform this function, at present only manual removal is possible for the majority of intensive care computer groups. We assessed the effects of artifact and its removal on the physiological data of 3 patients. Artifact was manually removed from 7 days of data in 4 parameters (heart rate, respiratory rate, systolic blood pressure [sbp] and transcutaneous oxygen [tcpO2]) by 3 independent observers. Six hour time periods were analysed. Median and mean values before and after the manual removal of artifact were compared. Overall 6.5% of data was removed as artifact. This was greatest for tcpO2 (9.9%) and sbp (10.6%), with smaller amounts for respiratory rate (2.8%) and heart rate (2.4%). Sbp showed a marked difference in the amount of data removed between patients, whereas tcpO2 data contained quite large volumes of artifact, but this was fairly consistent between patients. Removal of artifact affected mean values more than median values. One observer considered that both physiological and non-physiological artifact should be removed, whereas the other two observers removed only non-physiological artifact. Agreement in results between the latter was good. Our results suggest that inter-observer variability should have a minimal effect on values, once rules identifying the type of artifact to be removed are agreed. Removal of artifact did not have a clinically significant effect on results, but may be an important consideration in the statistical analysis of computerised physiological data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Cunningham, A G Symon, N McIntosh. 1994. The practical management of artifact in computerised physiological data.. https://doi.org/10.1007/bf01139872

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗