[The "inserted" condylar plate].

Abstract

Twelve extensive segmental and comminuted fractures of the femur affecting the metaphyseal areas (7 times proximal, 5 times distal) and the diaphysis were treated with extremely long condylar plates (16 to 20 holes). The condylar plates were inserted via a proximal and a distal incision leaving the Musculus vastus lateralis intact at the fracture site in all cases. Following standard preparation of the blade position using the seating chisel, the condylar plate was inserted behind the musculus vastus lateralis with the blade pointing towards the surgeon. The condyles or the trochanteric area were tilted slightly and the plate was turned 180 degrees and driven home. No screws were inserted in the area of the fracture, in particular, lag screws were not used. Ten out of 12 fractures healed without problems, in 2 cases bone grafting was necessary. Three main observations resulted from analysis of the operations and subsequent clinical and radiographical assessments. In the presence of relatively intact soft tissue covering, an astonishingly good reduction of the fragments was achieved after restoration of leg length and extension. In the healing process, callus formed rapidly and provided medial support. The bone structure was found to be more homogeneous than in the case for plate fixation involving several screws at the fracture site around which considerable fluctuations in bone density frequently occur. The application of condylar plates behind the musculus vastus lateralis by only proximal and distal incision for osteosyntheses of extensive multifragmental fractures is a further development of bridge-plating and can be recommended for long fractures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Wenda, M Runkel, L Rudig. 1995. [The "inserted" condylar plate].. https://doi.org/10.1007/bf02588734

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Postlaminectomy cervical dislocation in von Recklinghausen's disease. A case report.

STUDY DESIGN: A case of a 9-year-old girl with von Recklinghausen's disease who has acute tetraparesis caused by a complete dislocation of C6-C7 after a cervical laminectomy performed at another hospital. OBJECTIVES: To demonstrate the treatment difficulties of cervical spine abnormality associated with neurofibromatosis. SUMMARY OF BACKGROUND DATA: Craig and Govender have reported cases of neurofibromatosis of the cervical spine (1992). METHODS: The patient underwent emergency surgery starting with a posterior release of the articular facets and with the positioning of two Roy-Camille plates. The dislocation of C6-C7 was reduced by an anterior approach. Finally the Roy-Camille plates were removed, a plate was implanted posteriorly at the C6 and C7 joints, and a posterior cable was positioned around the C2-C3 posterior arches. RESULTS: More than 4.5 years after surgery, the patient's neurologic condition remains satisfactory. She can walk and run and has no sphincter disorders. CONCLUSIONS: The results underline the importance of simultaneous anterior and posterior surgical approaches in this disease.

Bone Plates

[Endoscope-assisted fixation of condylar fractures of the mandible].

The reduction and plate osteosynthesis of condylar fractures often require a wide extraoral approach with the risk of facial nerve palsy. The endoscopic technique is an alternative. Seven condylar fractures were operated on under endoscopic control. In three patients a newly developed device for endoscopically controlled plate application was clinically tested for osteosynthesis. In two cases fracture healing was achieved. In the third case the plate had to be removed early due to insufficient screw fixation. The new device and the application technique are described in detail. This technique may be helpful in further minimizing trauma surgery.

Bone Plates

[An osseointegrated micromanipulator as anchor for implantable hearing aid transducers. 1: Fitting to the surgical anatomy of the temporal bone and surgical technical properties].

The first electronic implantable hearing aids for patients with hearing loss are coupled to the ossicular chain or perilymph during implantation and are now available. Our new Tübingen implant designed for sensorineural hearing loss (SNHL) is the combination of an implantable microphone and piezotransducer. To avoid hearing losses during implantation, the Tübingen piezotransducer will be (1) fixed to the mastoid cavity and (2) positioned to one of the ossicular target points. This can be done with a micromanipulator which will be implanted together with transducer and microphone in the mastoid cavity. The manipulator weights 0.7 g. With four degrees of freedom, it allows highly secure and safe positioning of the transducer's probe tip to the ossicular chain under close to stereotactic conditions. The main advantages of the present micromanipulator are (1) easy handling during surgery, (2) the transducer's precise positioning to the ossicular target point with sufficient degrees of freedom, and (3) the transducer's stable fixation in the mastoid cavity in the final position. Following integrated safety as the leading principle, ossicular or inner ear injuries caused, e.g., by the patient's head movement or unintentional manual contact by the surgeon, are minimized. The micromanipulator is, as it were, the surgeon's vibration-free "artificial hand". The manipulator's development and its optimization to the mastoid cavity by test implantation in 50 human temporal bones are shown in detail. While coupling the transducer to the body of the incus, transducer, microphone, and micromanipulator can be implanted into 76% of all mastoid cavities without protrusion. In the case of transducers coupling to the long process of the incus, the protrusion-free implantation rate of the above-mentioned three implant modules is 78%.

Bone Plates