PubMed Health⌕ Search

PubMed · 7790795

The audible release associated with joint manipulation.

Abstract

OBJECTIVE: The objective of this paper is to review the literature on the audible release associated with manipulation. DATA SOURCES: Bibliographic information in pertinent articles and papers located in the MEDLINE database containing the keywords joint, joints, cartilage, crack, cracking, cavitation, crepitus and noise. STUDY SELECTION: All articles relevant to the objectives were selected. DATA EXTRACTION: All available data was used. DATA SYNTHESIS: The audible release is caused by a cavitation process whereby a sudden decrease in intracapsular pressure causes dissolved gasses in the synovial fluid to be released into the joint cavity. Once a joint undergoes cavitation, the force-displacement curve changes and the range of motion of the joint increases. The gasses released from the synovial fluid make up about 15% of the joint volume and consist of approximately 80% carbon dioxide. Habitual joint cracking does not correlate with arthritic changes, but does correlate with loss of grip strength and soft-tissue swelling. During the "crack" associated with a joint manipulation, there is a sudden joint distraction that occurs in less time than that required to complete the stretch reflexes of periarticular muscles. Theories on the cavitation mechanism were reviewed and new information on the cavitation process is introduced. In this paper, it is proposed that the cavitation process is generated by an elastic recoil of the synovial capsule as it "snaps back" from the capsule/synovial fluid interface. CONCLUSIONS: Because the sudden joint distraction during a manipulation occurs in a shorter time period than that required to complete the stretch reflexes of the periarticular muscles, there is likely to be a high impulse acting on the ligaments and muscles associated with the joint. This is an important conclusion, because others have proposed that reflex actions from high threshold periarticular receptors are associated with the many beneficial results of manipulation. This suggests that the cavitation process provides a simple means for initiating the reflex actions and that without the cavitation process, it would be difficult to generate the forces in the appropriate tissue without causing muscular damage.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Brodeur. The audible release associated with joint manipulation.. https://pubmed.ncbi.nlm.nih.gov/7790795/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗