Three-dimensional reconstruction of microleakage pattern using a sequential grinding technique.

Abstract

Dye penetration tests are very commonly used to detect the absence of a fluid seal at the tooth-restoration interface. Airlocks in the marginal gap, leaching of water-soluble tracers during processing, and the failure of only a few sections to allow interpretation of the full pattern, limit these tests to low reproducibility and precision. The purpose of this present study was to generate high-resolution three-dimensional images of waterfast tracer patterns. Cylindrical class V (3 mm diameter, 2 mm deep) dentine-bonded resin composite restorations in buccal coronal dentine were thermally cycled (1000 x, 8 degrees C, 55 degrees C, 30 s dwell at each temperature) and then silver stained using an initial vacuum (100 mmHg pressure). Each restoration was sequentially abraded from the free surface on wet 180 grit silicon carbide paper, producing up to 30 parallel surfaces at approximately 0.15 mm separation through the restoration down to the pulp. Images of the ground surfaces were captured, and assembled by a computer image analyser program to give a three-dimensional model of the tracer pattern. The maximum depths of tracer penetration below the reference surfaces were 3.00 mm, 2.09 mm, 3.16 mm and > 2.29 mm for the four specimens. Projections of the models were viewed from several directions with sections in various locations to allow investigation of the full tracer pattern. This method allows the creation of high-resolution three-dimensional tracer patterns.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M S Gale, B W Darvell, G S Cheung. 1994. Three-dimensional reconstruction of microleakage pattern using a sequential grinding technique.. https://doi.org/10.1016/0300-5712(94)90091-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The teaching of Class I and Class II direct composite restorations in European dental schools.

OBJECTIVES: The purpose of this descriptive study was to provide updated data on the teaching of Class I and Class II direct composite restorations in Europe as part of a survey of this aspect of the primary dental curriculum in Europe and North America. METHODS: Data on the teaching of posterior composite restorations and related matters were collected by means of a postal questionnaire sent to 185 dental schools known to exist in Europe. Non-respondents were sent a second questionnaire after two months. Further information pertaining to student requirements was sought after six months from all respondents. RESULTS: The response ranged from 92% for dental schools in Scandinavia to 40% from dental schools in Southern Europe with an overall response of 56%. All but four of the 104 participating schools were found to teach the use of composites in Class I and Class II, two-surface situations in at least premolar teeth. Contraindications and techniques taught for posterior composites varied within and between the country groupings of Northern and Central Europe. Scandinavia, Southern Europe and Eastern Europe. However, certain consensus views were identified. The experience of adverse biological reactions to the use of resin-based restoratives in European dental schools was found to be limited. CONCLUSIONS: Notwithstanding the variation in the response from the four geographic regions investigated and the relatively low overall response to the questionnaire, it is concluded that the data reported indicates that most dental schools in Europe teach the use of composites in selected Class I and Class II situations. However, considerable variation exists both within and between the regions investigated in relation to this teaching. Further research and consensus conferences should be planned to reduce variability across Europe in relation to the contraindications and techniques taught for posterior composites.

Composite Resins

Effect of finishing technique on the microleakage and surface texture of resin-modified glass ionomer restorative materials.

PURPOSE: The purpose of this study was to evaluate the effects of wet and dry finishing/polishing procedures on the microleakage and surface texture of resin-modified glass ionomer (RMGI) restorative materials. MATERIALS AND METHODS: Class V cavity preparations were made at the cemento-enamel junction (CEJ) on the buccal and lingual surface of 30 extracted human molars. The teeth were restored in three groups of 10 (20 preparations in each group) using Fuji II LC and Vitremer, both RMGIs, and Fuji II, a capsulated conventional glass ionomer cement (control). One restoration per tooth was finished/polished with copious applications of water and the other was finished/polished without water. All restorations were finished/polished using a sequence of four abrasive disks. Finishing/polishing was initiated according to manufacturers' instructions-immediately after light-curing Fuji II LC and Vitremer, and 15min after placement for Fuji II. The specimens were thermocycled and subjected to a silver nitrate leakage test. Each tooth was sectioned buccolingually and examined with an optical microscope at 40x to determine the extent of microleakage at enamel and dentin margins. The data were subjected to a non-parametric statistical analysis. To evaluate surface roughness after polishing, three disks each of Vitremer and Fuji II LC were fabricated in Teflon molds. One disk of each material was not finished/polished (control). The others were finished/polished using Sof-Lex abrasive disks. One specimen of each material was kept wet during all finishing/polishing procedures, while the other was kept dry. Atomic force microscopy was used to determine the average roughness (R(a)) of the specimens. RESULTS: For each material, microleakage at the enamel margin was very slight. Leakage of the conventional glass ionomer Fuji II was severe at dentin margins. Statistical analysis indicated that both Vitremer and Fuji II LC had significantly less leakage than Fuji II, and that Vitremer had significantly less leakage than Fuji II LC (p<0.05). Leakage at enamel margins was significantly less than at dentin margins. Differences related to wet and dry polishing were not statistically significant. Profilometry data indicated that polished specimens were rougher than those cured against a Mylar strip. Wet polishing created greater surface roughness than dry polishing. CONCLUSIONS: RMGIs rather than conventional glass ionomers should be used in Class V cavity sites to allow immediate finishing and to reduce the incidence of microleakage. Dry finishing of RMGIs with abrasive disks is recommended because it produces a smoother surface and does not contribute to microleakage. However, wet finishing of conventional glass ionomers is still recommended to avoid desiccation.

Composite Resins

A new electrical method for detecting marginal leakage of in vitro resin restorations.

OBJECTIVES: Ingress of bacteria at sites of marginal leakage has been suggested to cause pulpal inflammation. The purpose of this in vitro study was to evaluate the validity of a new electrical method to detect marginal leakage of restoratives by comparing the results obtained with those of a dye penetration test. METHODS: After cavities were prepared on the buccal coronal surfaces and root surfaces of 16 extracted non-carious human molar teeth, eight specimens were treated with a dentin bonding system (bonding group) and the other eight specimens were not treated (non-bonding group). Resin composites were filled in the cavities of all specimens, and physiological saline was applied to the margin of the restorative. Any excess saline was wiped off, leaving only the electrolyte, which had penetrated into the marginal gap. The change in conductance was measured continuously across the margin of each specimen during this process. The marginal leakage of specimens was confirmed using the dye penetration test, and the results were evaluated by the microleakage score. RESULTS: In both coronal and root surface cavities, the changes in conductance in the non-bonding group after filling were significantly larger than those of the bonding group (p<0.05). The change in conductance of each specimen correlated with the microleakage score (p<0.05). CONCLUSIONS: It was concluded that the relative electrical method could detect marginal leakage in both coronal and root surface cavities.

Composite Resins