PubMed HealthSearch

PubMed · 7868151

An extensive Markov system for ECG exact coding.

Abstract

In this paper, an extensive Markov process, which considers both the coding redundancy and the intersample redundancy, is presented to measure the entropy value of an ECG signal more accurately. It utilizes the intersample correlations by predicting the incoming n samples based on the previous m samples which constitute an extensive Markov process state. Theories of the extensive Markov process and conventional n repeated applications of m-th order Markov process are studied first in this paper. After that, they are realized for ECG exact coding. Results show that a better performance can be achieved by our system. The average code length for the extensive Markov system on the second difference signals was 2.512 b/sample, while the average Huffman code length for the second difference signals was 3.326 b/sample.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Tai. 1995. An extensive Markov system for ECG exact coding.. https://doi.org/10.1109/10.341837

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of the various electrocardiographic scoring codes for estimating anatomically documented sizes of single and multiple infarcts of the left ventricle.

It is clinically important to estimate the size of a myocardial infarction (MI) to predict patient prognosis, to determine the ability of a therapy to limit its size, and to evaluate its effect on left ventricular function. Various electrocardiographic methods have been used for these purposes but their accuracies have not been compared with each other using an identical reference population of anatomically measured infarcts. The capability of 4 electrocardiographic scoring methods (the Selvester score, the Minnesota code, the Novacode, and the Cardiac Infarction Injury Score) to estimate MI size was compared using anatomic MI size in a group of 100 deceased patients. All patients had a standard 12-lead electrocardiogram of sufficient quality to perform manual waveform measurements and without confounding factors such as ventricular hypertrophy, fascicular block, or bundle branch block. The location and size of the left ventricular infarction was measured postmortem using the anatomic method of Ideker et al. All methods' size estimates correlated best with anatomic MI size in the anterior location (r = 0.65 to 0.89). The Selvester score was superior in estimating the sizes of inferior (r = 0.70) and posterolateral (r = 0.74) infarcts. For multiple infarcts all methods performed poorly (r = 0.18 to 0.44).

Electrocardiography