PubMed HealthSearch

PubMed · 7874722

Transstenotic pressures: can there be a "low-tech" solution to a complex physiologic problem?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R W Smalling. 1994. Transstenotic pressures: can there be a "low-tech" solution to a complex physiologic problem?. https://doi.org/10.1002/ccd.1810330313

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical application of pulsed Doppler tissue imaging for assessing abnormal left ventricular relaxation.

Conventional assessment of left ventricular (LV) relaxation by calculating the time constant of LV pressure decay during the isovolumic diastole requires an invasive approach. Conversely, noninvasive parameters obtained by measuring isovolumic relaxation time and transmitral flow velocity often give inaccurate information. Using LV pressure curve, pulsed Doppler echocardiography, and pulsed Doppler tissue imaging in 38 patients with heart disease and 12 control subjects, we calculated the time constant and recorded transmitral flow velocity and motion velocities at the endocardial portions of the ventricular septum and LV posterior wall. Compared with the controls, patients exhibited a prolonged time constant, a decreased peak early diastolic velocity of the LV posterior wall, and a prolonged time interval from the second heart sound to the peak of the early diastolic wave. The time constant correlated well with the isovolumic relaxation time and various parameters calculated from the transmitral flow velocity, except in patients with elevated LV end-diastolic pressure. In all subjects, the time constant correlated negatively with the peak early diastolic velocity of the posterior wall and positively with the time from the second heart sound to the peak of the early diastolic wave. Thus, early diastolic parameters derived from the motion velocity of the LV posterior wall by pulsed Doppler tissue imaging were closely related to the time constant. This technique may allow noninvasive evaluation of abnormal LV relaxation in patients with various heart diseases.

Blood Flow Velocity

Natural course of isolated pulmonary valve stenosis in infants and children utilizing Doppler echocardiography.

Most natural history data regarding pulmonary stenosis (PS) were obtained from cardiac catheterization studies over 15 to 20 years ago. Selection bias in these studies often excluded patients with mild disease and infants. Today, Doppler echocardiography allows accurate serial assessments of stenotic lesions in patients of all ages. This study evaluates the natural history of PS utilizing serial Doppler examinations in the pediatric population. A total of 147 patients with PS and serial echocardiographic data were identified. Age at initial echocardiogram ranged from 2 days to 15 years, with a mean follow-up of 2.4 years. Sixteen of 56 patients (29%) initially evaluated within 1 month had a > or = 20 mm Hg increase in their peak systolic pressure gradient. Only 7 of 89 patients (8%) initially evaluated over 1 month had a > or = 20 mm Hg increase. Eleven of 40 newborn infants (28%) with mild obstruction had progression to moderate or severe PS compared with 10 of 68 patients (15%) initially evaluated over 1 month. Moderate PS in the newborn was also more likely to progress compared with older children. Of the 16 newborns with > or = 20 mm Hg increases, 8 developed the increase in < or = 6 months. In contrast, no patient aged >2 years whose initial gradient was <50 mm Hg developed severe PS. Mild PS may not be static, particularly in young infants. Progression in this age group occurs more often and more rapidly than in older infants and children.

Blood Flow Velocity