PubMed Health⌕ Search

PubMed · 7941419

Full-wave and half-wave rectification in second-order motion perception.

Abstract

UNLABELLED: Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Solomon, G Sperling. 1994. Full-wave and half-wave rectification in second-order motion perception.. https://doi.org/10.1016/0042-6989(94)90105-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perceived luminance depends on temporal context.

Brightness--the perception of an object's luminance--arises from complex and poorly understood interactions at several levels of processing. It is well known that the brightness of an object depends on its spatial context, which can include perceptual organization, scene interpretation, three-dimensional interpretation, shadows, and other high-level percepts. Here we present a new class of illusion in which temporal relations with spatially neighbouring objects can modulate a target object's brightness. When compared with a nearby patch of constant luminance, a brief flash appears brighter with increasing onset asynchrony. Simultaneous contrast, retinal effects, masking, apparent motion and attentional effects cannot account for this illusory enhancement of brightness. This temporal context effect indicates that two parallel streams--one adapting and one non-adapting--encode brightness in the visual cortex.

Contrast Sensitivity↗

Influence of local inhomogeneities induced in corneal ablation on the evolution of contrast sensitivity.

The presence of local inhomogeneities in corneal tissue after refractive surgery has an influence on visual performance. Here we focus on the corneal ablation associated with Lasik surgery and its effect on the modulation transfer function (MTF) that we obtained by modifying a personalized Kooijman model. Inhomogeneities induced by the ablation occur in the form of Gaussian-distributed refractive-index variations of a given correlation length. We show how variation of refractive-index deviation and correlation length (size) of the inhomogeneities allows us to obtain pairs of values that are able to achieve a MTF evolution similar to that observed for contrast sensitivity in the same patients. An estimate of the characteristics of the local effects is obtained.

Contrast Sensitivity↗

Perceived transparency of neutral density filters across dissimilar backgrounds.

We examine how the luminance distributions of overlaid surfaces affect the perception of transparency of neutral density filters. Pairs of neutral density filters were generated overlying variegated backgrounds of varying luminance distributions, and observers adjusted a single parameter of one filter until the pair appeared equally transparent. Physically identical filters appeared equally transparent on similar backgrounds, but did not appear equally transparent when backgrounds differed in luminance or contrast. Reducing luminance or contrast of the background decreased perceived transparency of the overlaying filter by a multiplicative factor. Observers matched perceived transparency of physically dissimilar filters by applying a linear trade-off between reflectivity and inner transmittance. In a second experiment, filters had their spatial structure altered in order to abolish the perception of transparency and appeared as patterned opaque disks, and observers equated perceived contrast of the two overlaid areas. Match settings gave results similar to the previous experiment, indicating that, in general, perceived transparency corresponds closely to the perceived contrast of the overlaid region.

Contrast Sensitivity↗