PubMed HealthSearch

PubMed · 8012486

Dynamic pip stabilizing splint.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M M Mignardi. Dynamic pip stabilizing splint.. https://doi.org/10.1016/s0894-1130(12)80042-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of treatment setup variation on beam's eye view dosimetry for radiation therapy using the multileaf collimator vs. the cerrobend block.

PURPOSE: The purpose of this study is to quantify and compare retrospectively the effects of treatment setup variation on beam's eye view (BEV) dosimetry for radiation therapy using a multileaf collimator (MLC) vs. cerrobend block. METHODS AND MATERIALS: A study was performed on a group of 18 patients with cancer of the head and neck, lung, and pelvis who were treated with irregularly shaped fields. The BEV dosimetry of the fields shaped with cerrobend blocks and the MLC was measured with films at the depth of dose prescription in a solid water phantom. A "one-half-leaf" insertion convention was used to shape the MLC. In addition, an average of 15 sequential daily port films was taken per patient during the course of radiotherapy. The port films were aligned with the prescription film for each patient. Systematic error and random error of treatment setup for each patient were calculated. The effects of setup variation were incorporated by convolving the patient portal imaging data with the corresponding BEV film dosimetry. Two parameters were used to quantify the BEV dosimetry. First, the field penumbra width was calculated, which represented the average of the normal separations between 20 and 80% isodose lines along the prescription outline. Second, the ratio of areas covered by the 90 and 20% isodose lines, A90/20, was determined. The BEV dosimetry was then characterized with and without the effects of treatment setup variation. In addition, the difference in BEV dosimetry between the cerrobend block and the MLC was used to estimate the corresponding changes in tumor control probability (TCP). These changes were also compared to the changes in TCP for the treatment with or without the effects of random setup variation. RESULTS: With or without daily setup variation, the use of cerrobend block was more favorable than the MLC in terms of the field penumbra width and A90/20 for all treatment sites. In the absence of daily variation, the MLC field penumbra width was on average 1.3 mm larger than that of the cerrobend block, and 0.9 mm larger in the presence of daily setup variation. Similarly, the ratio A90/20 of the cerrobend block was on average 0.03 larger than that of MLC without daily setup variation, and 0.02 with daily setup variation. The difference in field penumbra width and A90/20 between the MLC and the cerrobend block was slightly reduced due to the effects of daily setup variation. For both the cerrobend block and the MLC, daily setup variation produced a significant increase in the field penumbra width, 2.3 mm for the cerrobend block and 1.9 mm for the MLC, and a decrease in the A90/20, 0.06 for the former and 0.05 for the latter. The change due to the daily setup variation was about a factor of 2 larger than the changes due to replacing the cerrobend block with the MLC. Using the TCP model, the change in TCP due to the daily setup variation was more than a factor of 3 larger than the change in TCP due to replacing the cerrobend block with the MLC. It was noted that the average changes in the penumbra, the A90/20 and the TCP calculated for the patient population did not adequately describe the changes for the individual patient. CONCLUSION: Our results do not show significant dosimetric differences between the MLC and the cerrobend block in conventional radiation treatment, whether or not daily setup variation was taken into consideration. The effects of daily setup variation alone produced a larger dosimetric change. The same results were obtained when the data were applied to calculate changes in TCP. For optimal radiation therapy, efforts should be concentrated on reducing daily setup variation. Our results also demonstrate the importance of frequent evaluation of MLC treatment using electronic portal imaging devices.

Equipment Design

A computer-controlled conformal radiotherapy system. I: Overview.

PURPOSE: Equipment developed for use with computer-controlled conformal radiotherapy (CCRT) treatment techniques, including multileaf collimators and/or computer-control systems for treatment machines, are now available. The purpose of this work is to develop a system that will allow the safe, efficient, and accurate delivery of CCRT treatments as routine clinical treatments, and permit modifications of the system so that the delivery process can be optimized. METHODS AND MATERIALS: The needs and requirements for a system that can fully support modern computer-controlled treatment machines equipped with multileaf collimators and segmental or dynamic conformal therapy capabilities have been analyzed and evaluated. This analysis has been used to design and then implement a complete approach to the delivery of CCRT treatments. RESULTS: The computer-controlled conformal radiotherapy system (CCRS) described here consists of a process for the delivery of CCRT treatments, and a complex software system that implements the treatment process. The CCRS system described here includes systems for plan transfer, treatment delivery planning, sequencing of the actual treatment delivery process, graphical simulation and verification tools, as well as an electronic chart that is an integral part of the system. The CCRS system has been implemented for use with a number of different treatment machines. The system has been used clinically for more than 2 years to perform CCRT treatments for more than 200 patients. CONCLUSIONS: A comprehensive system for the implementation and delivery of computer-controlled conformal radiation therapy (CCRT) plans has been designed and implemented for routine clinical use with multisegment, computer-controlled, multileaf-collimated conformal therapy. The CCRS system has been successfully implemented to perform these complex treatments, and is considered quite important to the clinical use of modern computer-controlled treatment techniques.

Equipment Design