PubMed HealthSearch

PubMed · 8114881

Clinical problem-solving: assessing aortic valvular insufficiency.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Burger, M Kamalesh. 1994-03-31. Clinical problem-solving: assessing aortic valvular insufficiency.. https://doi.org/10.1056/nejm199403313301319

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Severe aortic regurgitation immediately after mitral valve annuloplasty.

We report a case of severe aortic regurgitation occurring immediately after the insertion of a mitral annuloplasty ring. On transesophageal echocardiography, regurgitation was found to originate from the retracted left coronary cusp. On direct examination, part of the aortic wall was folded, but no suture could be identified. It was reasoned that tension created by the ring caused the retraction. The problem was corrected by releasing three sutures on the ring. Postoperative course was uneventful.

Aortic Valve Insufficiency

In vitro analysis of colour Doppler flow with the use of proximal isovelocity surface area: improved flow estimates using a nonhemispherical model.

OBJECTIVE: To examine the geometry of the proximal isovelocity surface area (PISA) envelope and its associated isotach, and to evaluate the accuracy of two models of calculating volumetric flow by using the PISA technique. DESIGN: A new model for determining isotach geometry from the PISA envelope was developed and tested in an in vitro simulation. SETTING: Echocardiography Laboratory, Hotel Dieu Hospital, Kingston, Ontario. MATERIALS AND METHODS: PISA envelopes were visualized using an in vitro flow simulator with a series of sharp-edged orifices (2.5 to 16 mm diameter) at a range of flow rates (10 to 110 mL/s). INTERVENTIONS: Flow calculations based on the traditional hemispherical geometric assumption for the isotach and the new model were made and compared with measured flow rates. MAIN RESULTS: The hemispherical model systematically and significantly underestimated flow. The nonhemispherical model, which requires measurement of both the height (a) and lateral width (2d) of the PISA envelope, provided improved estimates of flow. CONCLUSIONS: The nonhemispherical model provides a better estimate of flow through an orifice. Flow rate Q can be calculated directly from the size of the PISA envelope and the aliasing velocity (VA) by using the relationship Q = (3.14d2 + 5.97da + 1.37a2)VA or can be read from a nomogram.

Aortic Valve Insufficiency