Data compression of the exercise ECG using a Kohonen neural network.

Abstract

The goal for any data compression scheme is to maximize compression while minimizing distortion. This is particularly true for measurement sensitive electrocardiographic data. Many different approaches have been taken to achieve this goal. One common technique used in image and speech data compression, vector quantization, was selected for this study. Central to vector quantization is the creation of a codebook of vectors. Creating the best possible codebook will enable the best possible data compression. A neural network was used to create a codebook of vectors that attempt to span the low-frequency data space. Since these vectors are potentially the less critical areas of the electrocardiographic signal, less important information will be subjected to increases in distortion. The Kohonen paradigm used in this study is an unsupervised neural network that adapts the codebook vectors based on distance measurements and controls the scope of the changes based on time. This network has been shown to work well with image and speech data, but to the author's knowledge has not been used on electrocardiographic data. The compression of the signal comes from inserting the address of the codebook vector that best represents the original vector in place of the vector. A test is first performed to determine if the distortion between the original and the replacement vector is within a present limit. If it is, the address is inserted. If the distortion is too large the original vector will be retained. Typically, the QRS segment and possibly the T segment will be preserved. The new compressed file can be further reduced by lossless techniques to increase the compression ratio.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J D McAuliffe. 1993. Data compression of the exercise ECG using a Kohonen neural network.. https://pubmed.ncbi.nlm.nih.gov/8189153/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Use of a screening device for sleep apnea in clinical practice].

About 2-4% of adults suffer from obstructive sleep apnea (OSA), which is the most common sleep-related breathing disorder (SRBD). Repetitive obstructions of the upper airway mean that it is associated with hypertension and an elevated cardio- and cerebrovascular morbidity, which can be lowered by means of effective therapy. These patients cannot be treated correctly unless they are identified early in the course of the condition. Therefore, this study evaluated the use of the microMESAM screening device (known up to December 2005 as the "ApneaLink") in 61 patients in whom SRBD was suspected. The device proved reliable and practical in application.

Diagnosis, Computer-Assisted↗

Computer-aided diagnosis for improved detection of lung nodules by use of posterior-anterior and lateral chest radiographs.

RATIONALE AND OBJECTIVES: We developed a computerized scheme for detection of lung nodules in the lateral views of chest radiographs, in order to improve the overall performance in combination with the computer-aided diagnostic (CAD) scheme for posterior-anterior (PA) views. MATERIALS AND METHODS: We used 106 pairs of PA and lateral views of chest radiographs (122 lung nodules) for development of the CAD scheme. In the CAD scheme for lateral views, initial candidates of lung nodules were identified by use of a nodule enhancement filter based on the edge gradients. Thirty-four image features extracted from the original and the nodule-enhanced images were used for the rule-based scheme and for artificial neural networks (ANNs) for removal of some false-positive candidates. The computer performance was evaluated with a leave-one-case-out test method for ANNs. For PA views, we used the existing CAD scheme, which was trained with one-half of 924 chest images and then tested with the remaining images. RESULTS: When the CAD scheme was applied only to PA views, the sensitivity in the detection of lung nodules was 70.5%, with 4.9 false positives per image. Although the performance of the computerized scheme for lateral views was relatively low (60.7% sensitivity with 1.7 false positives per image), the overall sensitivity (86.9%) was improved (6.6 false positives per two views), because 20 (16.4%) of the 122 nodules were detected only on lateral views. CONCLUSIONS: The CAD scheme by use of lateral-view images has the potential to improve the overall performance for detection of lung nodules on chest radiographs when combined with a conventional CAD scheme for standard PA views.

Diagnosis, Computer-Assisted↗

Improvement of the detection of myocardial ischemia thanks to information technologies.

BACKGROUND: The standard 12-lead ECG remains one of the basic investigations for the early detection and assessment of acute coronary syndromes. It is easy to perform, anywhere and anytime, and can be digitally transmitted within minutes to an emergency medical service for remote advice and triage. But the conventional ST-segment deviation criteria are of limited diagnostic accuracy. The purpose of this study is to investigate how much the use of computerized ECG techniques based on the measurement of the serial spatiotemporal ECG changes could improve the detection accuracy of transmural myocardial ischemia. METHODS: We considered the serial changes of continuous 12-lead ECGs of 90 patients undergoing elective percutaneous coronary angioplasty (PTCA) recorded during balloon inflation as an experimental model of ECG changes induced by coronary artery occlusion. The spatiotemporal ECG changes were measured according to the CAVIAR method and assessed by multivariate discriminant analysis in reference to serial changes of control recordings and standard ECG criteria. RESULTS: The diagnostic accuracy of the CAVIAR criteria for ischemia detection was 97%, with sensitivity of 98% and specificity of 96%, whereas the diagnostic accuracy of the conventional ST-segment criteria was 74%, with sensitivity of 60% and specificity of 88%. The increase of overall performance was obtained for all the occlusion locations. CONCLUSIONS: Computer-assisted quantitative serial ECG analysis, taking into account the spatiotemporal changes of the QRS and T waves, would provide the physician with additional information for significantly improving the detection of transmural myocardial ischemia.

Diagnosis, Computer-Assisted↗