Automatic fracture reduction with a computer-controlled external fixator.

Abstract

The reduction of fractures by means of an Ilizarov's fixator is obtained by successively shortening or lengthening the rods. This entails that all reduction operations of the fracture stumps be performed with a series of empirical attempts, requiring great experience and manual dexterity in the surgeon. Moreover this process involves a long exposure of both physician and patient to potentially harmful radiation due to the continuous checking of the intermediate positions on the X-ray image intensifier. In order to overcome these limits a new device has been conceived, based on the application of three stepper-motors on three-rods. Its basic principle is functionally very similar to Ilizarov's prototype. The relative motions between the two frames are carried out by controlling the three actuators with a computer, which processes the number of required steps on the basis of an algorithm, starting from a few inputs supplied by the surgeon. This article illustrates the functional kinematic study necessary for the complete automation of the reduction process. Also considered is the complex problem of the reduction trajectory definition, intended as a sequence of configurations of partial correction, obtained by formalizing in geometrical terms the empirical criteria followed by the orthopaedic surgeon in reducing fractures. Such a sequence is intended to be a suggestion for the surgeon who can visualize and possibly interact with the system to determine a trajectory harmless for the soft tissues surrounding the bone.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Viceconti, A O Andrisano, A Toni, A Giunti. 1994. Automatic fracture reduction with a computer-controlled external fixator.. https://doi.org/10.1016/1350-4533(94)90027-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Swan-neck deformity as a complication of the Agee technique.

Unstable dorsal fracture dislocations of the PIP joint of a finger commonly result in joint stiffness following immobilization or open reduction and internal fixation (Green and Rowland, 1984). The Agee dynamic external fixator, or force couple splint (Agee, 1978; 1987), was introduced in an attempt to avoid this complication and maintains a concentric reduction whilst allowing a full range of joint movement. The splint is constructed from three Kirschner wires and is activated by a single rubber band. A force couple is created across the proximal interphalangeal joint levering the base of the middle phalanx towards the palm whilst simultaneously lifting the distal end of the proximal phalanx dorsally to restore joint reduction. However, this technique is not without complications (Agee, 1987). We report a swan-neck deformity resulting from this treatment.

External Fixators