PubMed Health⌕ Search

PubMed · 8214774

Compliance changes in venous insufficiency.

Abstract

In 37 patients (69 limbs) referred to Mayo Clinic's Vascular Center for possible venous valvular insufficiency in the lower limb, calf muscle pump function, calf compliance, and venous refilling times were measured by strain gauge plethysmography techniques. Patient limbs were separated into four categories based on 90% refilling time (T90) following fifteen deep knee bends: normal (n = 16), mild/moderate (n = 28), severe (n = 16), and edema of nonvenous origin (n = 9). Pump function was assessed in actual pumping volumes (mL) and in percent pumping volumes (mL/100 mL), and was reduced in all noncontrol categories. Calf compliance was assessed in actual volume change (mL/mmHg) and in percent volume change (mL/100 mL/mmHg) and was increased in the severe reflux category. Ten study patients had 1 normal category limb and 1 reflux category limb. Paired analysis of these limbs showed pump function to be decreased and calf compliance to be increased in the diseased group limbs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Sutor, J L Heser, T W Rooke. 1993. Compliance changes in venous insufficiency.. https://doi.org/10.1177/000331979304401003

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A rigorous method for evaluation of the 6D compliance of external fixators.

External fixators are standard devices to stabilize bone fractures and their compliance aims at producing an interfragmentary motion that promotes rapid and successful healing. While evaluation of their axial compliance is a routine test, the quantification and interpretation of their full 6 x 6 compliance matrix is an extensive and delicate task. In this context, the objective of this study was to develop, validate and demonstrate the potential of a rigorous method to quantify their 6 x 6 compliance matrix. An experimental system was developed to apply six independent static forces and moments to an external fixator in the field of view of two infrared cameras quantifying the induced motion. The system was then tested with a calibration structure which compliance could be calculated analytically and numerically. Finally, the system was applied to compare three configurations of a commercial external wrist fixator. The results of the method proved to be reproducible and highly consistent with the linear elasticity theory in the physiological range of small deformations. A rigorous method for evaluation of the 6D compliance becomes therefore available for research in mechanobiology of fracture healing by external fixation.

Compliance↗

Fatigue of packable dental composites.

OBJECTIVE: The purpose of the study was to measure the fatigue properties of four dental resin composites using a dynamic mechanical analysis and to relate the results with viscoelastic properties. METHODS: Dynamic torsional loading was conducted at resonance at 30-50Hz. Specimens were thoroughly cured and tested dry at 21 degrees C. RESULTS: All of the specimens showed a loss of strength following repeated stress, due to material fatigue. The material with the highest shear modulus had the lowest damping and the highest fatigue strength. SIGNIFICANCE: Dental composites exhibit a modest loss of strength due to fatigue. Since mastication involves many cycles of stress during the life of a restoration, fatigue properties should be taken into account in restoration design.

Compliance↗