PubMed HealthSearch

PubMed · 8249924

Comments on incisor torque control.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P C Kesling. 1993. Comments on incisor torque control.. https://doi.org/10.1016/s0889-5406(05)80427-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Concept and development of a measuring system for in vivo recording of orthodontically applied forces and torques in the multiband technique. Part I.

The cause of tooth movement with a multiband or multibracket appliance is the force system in the bracket, which is generated by an archwire and transmitted by a bracket to the respective tooth. Continuous arch wires are, from the biomechanical point of view, a statically multiply undetermined system. Quantitative determination of the forces and torques acting at the individual teeth, and thus observance of a non-critical level of applied forces, is therefore extremely problematic in practice, the force is applied by the orthodontist more or less "intuitively" on the basis of recommendations evolved in theory and in vitro. The measuring technique presented in this paper is designed to permit these force systems to be recorded in vivo for the first time, allowing account to be taken of the individual situation "tooth-periodontium-bone". Evolvement of an appropriate measuring principle was followed by development of the individual components of the measuring system. The results of the subsequent initial in vitro test series offer the prospect of successful clinical application.

Dental Stress Analysis

Goal-oriented positioning of upper second molars using the palatal intrusion technique.

This article describes an orthodontic mechanical variation to reduce prominence of the palatal cusp of the upper second molar and to correct buccal crossbites in the molar area. By using a modified transpalatal arch with a soldered spur, a button bonded to the palatal surface of the second molar, and an elastic chain intrusion of the palatal cusp with control of buccal root torque is accomplished. The palatal intrusion technique provides a simple and very efficient approach to correct upper second molar position.

Dental Stress Analysis

Frictional resistances in stainless steel bracket-wire combinations with effects of vertical deflections.

This research evaluated the effects of different bracket-wire combinations and second-order deflections on kinetic friction. Thirteen different brackets, six with 0.018 x 0.025 inch slots and seven with 0.022 x 0.028-inch slots were evaluated with six different sizes and shapes of stainless steel orthodontic wire, i.e., 0.016, 0.016 x 0.022, 0.017 x 0.025, 0.018, 0.018 x 0.025 and 0.019 x 0.026 inch for four second order deflections of 0.00, 0.25, 0.50, and 0.75 mm. The wires were ligated into the brackets with elastomeric modules. Bracket movement was implemented by means of an Instron universal testing instrument (RMO, Denver, Colo.), and frictional forces were measured by a tension load cell and recorded on an X-Y recorder (Hewlett-Packard, Anaheim, Calif.). Second-order deflection was created by a specially designed and machined testing apparatus that allowed two alternate pairs of the four total brackets to be offset in increments of 0.25 mm. The kinetic frictional force increased for every bracket-wire combination tested as the second-order deflection increased. Friction also increased with an increase in wire size, whereas rectangular wires produced greater friction than round wires. Bracket designs that limited the force of ligation on the wire generated less friction at low second-order deflections (0.00 and 0.25 mm).

Dental Stress Analysis