[The Mecron-titanium prosthesis].

Abstract

To answer the question of the duration of cementless hip-endoprostheses 59 Mecron-Titanium-prosthesis were compared with a contingent of 56 prostheses with a Chromium-Cobalt-Molybdenum-stem. The clinical as well as the radiological results are compared in a 2-5 years follow up. It is shown, that the Titanium stem reaches 93.2% "very good" to "satisfactory" results in the Merl d'Aubigné-Scheme the Chromium-Cobalt-Molybdenum-stem in comparison only in 85.71%. The x-ray pictures show, that the Titanium stems cause less sclerosis of the femur than the Chromium-Cobalt-Molybdenum-stems. The radiologic signs of loosening of both stems nevertheless do not correlate with the subjective and clinical results. It has to be mentioned that it was not possible to carry out a complete following up of all patients on the fact that some did non appear to the follow-up-examination.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Herzberger, T Hill, K Rossak. [The Mecron-titanium prosthesis].. https://doi.org/10.1055/s-2008-1040068

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Corrosion considerations in the brazing repair of cobalt-based partial dentures.

Cobalt-based alloys (Co-Cr-Mo) are usually used in dentistry as frameworks for removable partial dentures. In their basic form these structures function successfully. However, modifications or repairs of the frameworks may reduce their resistance to corrosion and, as a consequence, may provoke biologic reactions in the soft tissues. These reactions may be the result of different types of alloys that contact each other and, in the presence of saliva (based on potential differences), produce a galvanic cell. In this study, a clinical situation after repair of a removable partial denture was examined. The metallographic study of the prosthesis revealed a brazed zone where a gold braze was joining the Co-Cr-Mo framework with a Co-Cr-Ni type alloy (without Mo). The latter revealed signs of corrosion. Various electrochemical parameters (Ecorr, Ecouple, icorr, icouple) of these alloys were analyzed in the laboratory. The Co-Cr-Ni alloy had the lowest nobility and underwent galvanic corrosion in a galvanic couple with gold braze.

Chromium Alloys

Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro.

Titanium is used to fabricate spherical and bar attachments for overdentures on osseointegrated implants. This in vitro study investigated the long-term effects of commercially pure titanium on the retention force of telescope crowns with conical interface. Combinations of various materials for the inner and outer crowns were tested. Telescope crowns of pure titanium showed retention force characteristics comparable to telescope crowns fabricated conventionally in a precious alloy.

Chromium Alloys

Titanium for prosthodontic applications: a review of the literature.

Titanium has become a material of great interest in prosthodontics in recent years. A growing trend involves the use of titanium as an economical and biocompatible replacement for existing alloys for fixed and removable prostheses. However, long-term results of titanium casting, joining, and porcelain bonding have to be evaluated before this wonder metal can be used routinely in clinical dentistry. This article describes the development and properties of titanium and reviews the literature related to the use of titanium in prosthodontics, for the purpose of evaluating the present status and future trends in its use.

Chromium Alloys