PubMed Health⌕ Search

PubMed · 8338627

Fetal renal biopsy: technique development.

Abstract

Fetal/neonate kidneys obtained at the time of autopsy were utilized to determine a suitable needle biopsy gauge to obtain renal parenchyma for histologic evaluation. Twenty-one fresh kidney specimens from 11 fetuses/neonates between 16-40 weeks gestation were used to obtain needle biopsies using 20-, 18-, 16-, and 14-gauge biopsy catheters. The specimens were graded according to the presence of normal histologic features of renal parenchyma. Seventy-five renal biopsies were obtained. The biopsy histology was interpreted using a grading system based on the presence of normal features of the renal parenchyma. Sixty-three (84%) of the samples were graded histologically as adequate (cortex or medulla present). Samples with both cortex and medullary structures present (completely adequate) were obtained in 39/63 (62%) of these adequate biopsies. The 14- and 16-gauge biopsy catheters gave the best results, respectively yielding 79 and 69% completely adequate biopsies. This is in contrast to the 20- and 18-gauge catheters that respectively yielded 35 and 25% completely adequate biopsies. Our initial results indicate that adequate kidney biopsies can be obtained. However, the current technique is associated with core sample disruption when the smaller gauge catheters are used. This could account for the low rate of completely adequate samples with the smaller gauge catheters. A different sampling technique is needed to overcome sample disruption, to determine the smallest catheter gauge that will yield a suitable tissue sample for histologic evaluation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W A Campbell, H T Yamase, C A Salafia, A M Vintzileos, J F Rodis. Fetal renal biopsy: technique development.. https://doi.org/10.1159/000263762

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.

PURPOSE: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet. MATERIALS AND METHODS: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion. RESULTS: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal. CONCLUSIONS: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.

Biopsy, Needle↗