PubMed Health⌕ Search

PubMed · 8344978

Percutaneous aspiration embolectomy.

Abstract

Percutaneous aspiration thromboembolectomy (PAT) for management of a spontaneous arterial embolus, or following a complication of balloon angioplasty, was initially described in 1984. Instrument developments using a new clot aspiration system have facilitated this procedure. We report a case where PAT was successful in retrieving a spontaneous arterial embolus, and describe this new technique. We feel that PAT broadens the armamentarium of the vascular surgeon in the management of emboli to the distal circulation, where the results for operative embolectomy are frequently less than ideal.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K W Sniderman, P G Kalman, M J Quigley. 1993. Percutaneous aspiration embolectomy.. https://pubmed.ncbi.nlm.nih.gov/8344978/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Preclinical testing of a new clot-retrieving wire device using polyvinyl alcohol hydrogel vascular models.

INTRODUCTION: Cerebral embolism is the principal cause of cerebral infarction. Recently, mechanical embolectomy has been proposed as an effective method. We performed a preclinical evaluation of a new mechanical clot-retrieving wire. METHODS: This clot-retrieving wire consisted of three nitinol loops at the tip of a microguidewire. These three loops could be collapsed into a 0.018-inch wire compatible microcatheter. Each loop was 8 mm long and 3.5 mm wide. For simulation, polyvinyl alcohol (PVA) vascular anatomical models of the human carotid (eight models) and vertebrobasilar (three models) circulation were constructed. A pulsatile flow circulation system was used. Embolic clots were produced using pig blood plasma. The microcatheter and the microguidewire were advanced beyond the clot. The wire was then exchanged for the retrieving wire. The microcatheter was then pulled slightly back to open the loops. The clot was then caught by withdrawal of the system. Once caught, the clot was retrieved to the guiding catheter tip. We investigated the following points: ease of device deployment, clot capture ability, clot removal against blood flow and removal of the clot out of the introducer system. RESULTS: A total of 104 procedures were performed in 11 PVA models and evaluated. The drop rate was 19%. We succeeded in partial and total recanalization in 51.0% of the procedures (53/104) within 30 minutes. CONCLUSION: This new clot-retrieving wire could be useful for mechanical clot extraction in stroke.

Embolectomy↗