PubMed HealthSearch

PubMed · 8354776

A noteworthy study.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J O Grippo. 1993. A noteworthy study.. https://doi.org/10.14219/jada.archive.1993.0158

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Features of human jaw design which maximize the bite force.

A linear programming model, operating in a three-dimensional coordinate system, was written to study the effect on unilateral maximum bite forces (MBFs) of small changes in the design of human jaws. Under some conditions the MBF was larger on a more anterior tooth than a more posterior tooth for a given bite direction. The MBF was increased (i) as the bite force was tilted forward, (ii) as the jaw was opened if its direction was kept perpendicular to the occlusal plane of the lower jaw, (iii) by placing teeth nearer the midline, (iv) by raising the height of the teeth for forward bite forces, and (v) by tilting forward the articular surface of the condyle (equivalent to creating an articular eminence). Increasing the distance between the condyles spread the load more evenly between the two joints. The articular eminence was the only design feature which seemed to be clearly related to increasing the MBF.

Bite Force

Effect of splinting on load distribution of extracoronal attachment with distal extension prosthesis in vitro.

Previous reports have suggested that the restoration of distal extension edentulous areas with an extracoronal precision attachment partial denture necessitates splinting of abutments. However, the number of splinted teeth remains controversial. In this study, strain gauge technology was used to monitor stresses induced around the abutment and in the distal extension area under different loads as a function of the number of splinted abutments. Three strain gauges were installed in the outer buccal, lingual, and distal surfaces of the abutment to record stresses in the three planes of motion, and another gauge was placed under the distal extension base. The reduction of the number of splinted units from three to two resulted in an insignificant increase of stresses recorded, whereas reduction of the number from two to one resulted in a significant increase of stresses nine times greater than the three-unit splint values. On the basis of this in vitro model, at least two teeth on each side should be splinted when extracoronal distal extension attachment prostheses are used.

Bite Force