PubMed HealthSearch

PubMed · 8356282

Single-element transducers.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W D O'Brien. 1993. Single-element transducers.. https://doi.org/10.1148/radiographics.13.4.8356282

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Inertial cavitation produced by pulsed ultrasound in controlled host media.

The purpose of this work is to provide measurements in well-characterized media in order to better understand inertial (transient) cavitation phenomena. Focused transducers with megahertz center frequencies (2.5 MHz, 4.3 MHz) and a clinical diagnostic ultrasound system (4.0 MHz) was used to generate pulsed ultrasound to induce cavitation. An improved active cavitation detector which utilizes a highly focused transducer with much higher center frequency (30 MHz) was used to measure the threshold of inertial cavitation. In order to study the effect of the concentration of nucleation agents on cavitation thresholds, experiments were conducted in distilled water seeded with polystyrene particles. Inertial cavitation thresholds were measured for various concentrations of polystyrene particles. It was observed that the threshold decreased from 2.5 MPa at concentration of about 10(6) particles/ml to 1.6 MPa at a concentration of about 10(9) particles/ml. The effect of the concentration is not significant for smaller changes of concentration. Measurements of the cavitation thresholds were then made in specially developed phantom materials to study the effect of viscosity on the cavitation threshold when surface tension and other mechanical properties of the materials are kept relatively constant. Experimental results show that the threshold increases with increasing viscosity, consistent with theoretical predictions. Cavitation was also detected in water seeded with polystyrene particles using a clinical ultrasound system at an acoustic pressure of 3.84 MPa. Results are comparable with those obtained in the laboratory using a 4.3-MHz focused transducer.

Transducers

Ultrasonic beam-plotting with very small spheres.

A method of pulse-echo ultrasonic beam plotting is described. It differs from traditional pulse-echo beam plotting in that the ultrasonic pulses are scattered off a totally isolated sphere rather than a sphere suspended on a wire. The method also allows extremely small spheres to be used thus providing greater resolution. It is demonstrated that pulse-echo beam plotting using spheres of different size produces different iso-echo amplitude curves.

Transducers

An improvement in the range resolution of ultrasonic pulse echo systems by deconvolution.

Ultrasonic pulse echo systems are often limited in range resolution by the bandwidth of the piezoelectric transducer. Significant improvements in the range resolution of such systems can be obtained by minimizing the effects of the transducer's dynamic response on the overall pulse echo process. An approach to minimize the effects of the transducer is developed from linear system and impulse response techniques. In essence, the pulse echo voltage of interest is deconvolved with a pulse echo reference voltage which is obtained from an air/water interface in the nearfield of the transducer . A computer study of the pulse echo process and the deconvolution process is presented to illustrate the nature of the improvement in range resolution for several cases of interest. Finally, experimental results are presented to illustrate the improvement using commercially available transducers.

Transducers