Glaucoma occurring after closed vitrectomy.

Abstract

Six of 20 eyes developed postoperative glaucoma within two to ten days after closed vitrectomy for vitreous hemorrhage. Intraocular pressure was greater than 40mm Hg in all six eyes, and three developed pressure greater than 60 mm Hg. Intraocular pressure in four eyes was controlled with medical antiglaucoma therapy and two eyes required anterior chamber irrigation. Six months postoperatively three of the eyes had normal pressures, one was hypotonous, and two developed increased intraocular pressure secondary to angle neovascularization. Three of the 14 eyes that did not develop glaucoma developed a cellular accumulation in the anterior chamber. The glaucoma was caused mainly by obstruction of the trabecular meshwork by degenerated red blood cells known as ghost cells. The cells may be identified by phase-contrast examination of anterior chamber aspirates. Glaucoma can be prevented through irrigation of the vitreous cavity at the time of vitrectomy ensuring that no cells and debris are left behind to migrate into the anterior chamber and obstruct the trabecular meshwork. This type of glaucoma is caused mainly by ghost cells, whereas hemolytic glaucoma is caused mainly by macrophages and red blood cell debris.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D G Campbell, R J Simmons, F I Tolentino, J W McMeel. 1977. Glaucoma occurring after closed vitrectomy.. https://doi.org/10.1016/0002-9394(77)90193-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Examination of the orbit using a non-ophthalmologic ultrasound equipment].

Ophthalmic examinations were performed for determining the suitability of seven different types of non-ophthalmic ultrasound equipments for ophthalmological purposes. According to the results, the instruments with probes of 5 MHz or higher frequency are appropriate for certain screening ophthalmological purposes in hospitals where ophthalmic ultrasound instrument is still missing. The possible indications are: approximate estimation of axial eye length for intraocular lens calculation, and visualization of gross intraocular and orbital diseases, such as retinal detachment, tumours, foreign bodies etc. In case of pathological result or in case of axial eye length different from the average value, the high resolution ophthalmological ultrasound examination is mandatory. The modern colour-coded Doppler ultrasound equipments were found suitable for the examination of the circulation of the eye and orbit.

Eye Diseases

[MR imaging of intraocular lesions--a comparison with CT].

Thirty-two intraocular lesions were studied with magnetic resonance (MR) imaging and computed tomography (CT). These lesions included retinoblastoma (n = 11), uveal melanoma (n = 6), metastatic choroidal tumor (n = 3), choroidal hemangioma (n = 2), retinochoroiditis (n = 6) and Coats' disease (n = 4). MR imaging was superior to CT in the depiction of intraocular masses and retinal detachment. Gd-DTPA enhanced MR imaging was more useful than contrast enhanced CT in evaluating the contrast enhancement of intraocular tumors. Differential diagnosis of intraocular tumors was difficult with both MR imaging and CT. Intratumoral calcification was noticed on CT in nine cases of retinoblastoma. It was concluded that MR imaging, including contrast enhancement study, is more useful than CT in the evaluation of intraocular lesions, except for calcification, and contrast enhanced CT may be unnecessary in the diagnosis of intraocular lesions.

Eye Diseases

Examination of macular vitreoretinal interface disorders with monochromatic photography.

Monochromatic light accentuates details of different retinal layers because of its variable absorption and reflectance by structures both within and above these layers. Monochromatic photography was used to examine macular vitreoretinal interface abnormalities in 19 patients. Short wavelength photographs (490 nm) provided the best detail of inner retinal abnormalities, including epiretinal membranes, vitreoretinal traction, and the internal surface of confluent macular edema (pseudocyst). Although 540-nm red-free photography provided acceptable photographs, it did not provide optimal detail of inner or deep retinal abnormalities. Longer wavelengths, 585 and 610 nm, best disclosed the extent of deep retinal abnormalities, including the extent of confluent macular edema (pseudocysts) and retinal detachment that surrounded macular holes. The addition of short- and long-wave-length photography to traditional red-free photography may provide better localization, understanding, and documentation of the three-dimensional relationships in macular vitreoretinal interface disorders.

Eye Diseases