PubMed Health⌕ Search

PubMed · 8427121

Matching based on quantitative coronary angiography as a surrogate for randomized studies: comparison between stent implantation and balloon angioplasty of native coronary artery lesions.

Abstract

Although intracoronary stenting has been advocated as an adjunct to balloon angioplasty to circumvent late restenosis, its effectiveness has not yet been verified. Therefore the aim of this study was to determine the differences in the immediate and long-term changes in stenosis geometry between Wallstent implantation and balloon angioplasty in native coronary artery lesions. To obtain two study populations with identical baseline stenosis characteristics, patients were matched for lesion site, vessel size, and minimal luminal diameter. Only patients undergoing elective and successful coronary intervention of a native coronary artery, in whom a control angiographic study had been performed, were included. A total of 186 patients (93 in each group) were selected. The coronary angiograms were analyzed with the computer-assisted cardiovascular angiographic analysis system. Matching was considered adequate, since there was an equal number of lesion sites in each study population and there were no differences in baseline reference diameter and minimal luminal diameter. Wallstent implantation resulted in a significantly greater increase in minimal luminal diameter (from 1.22 +/- 0.34 mm to 2.49 +/- 0.40 mm, p < 0.00001) compared with balloon angioplasty (from 1.21 +/- 0.29 mm to 1.92 +/- 0.35 mm, p < 0.00001). Despite a greater decrease in minimal luminal diameter after Wallstent implantation (0.48 +/- 0.74 mm) than after balloon angioplasty (0.20 +/- 0.46 mm), the minimal luminal diameter at follow-up was significantly greater after stent implantation (2.01 +/- 0.75 mm vs 1.72 +/- 0.54, p < 0.0001). It was concluded that Wallstent implantation results in a superior immediate and long-term increase in minimal luminal diameter compared with balloon angioplasty. The larger initial gain after stent implantation compensates for the late loss, and thus an improved initial result and not lessened neointimal hyperplasia is responsible for a reduced incidence of restenosis. Studies based on matching of angiographic variables are a surrogate for randomized studies, forecasting their results and offering insight into the effects of different interventional techniques. Moreover, these studies yield statistical information that may be helpful for the proper design of a randomized study (sample size, type II error).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P P de Jaegere, W R Hermans, B J Rensing, B H Strauss, P J de Feyter, P W Serruys. 1993. Matching based on quantitative coronary angiography as a surrogate for randomized studies: comparison between stent implantation and balloon angioplasty of native coronary artery lesions.. https://doi.org/10.1016/0002-8703(93)90005-t

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stent fracture: an unusual cause of late restenosis after sirolimus-eluting stent placement.

Stent fracture is uncommon but may have consequences including restenosis. To date, stent fractures reported have been related to aggressive post dilation. We describe a case that involves fracture of a stent deployed to nominal pressure. Unlike most stent fractures reported that involve stent struts only our case demonstrated circumferential disruption with complete separation of the stent segments.

Angioplasty, Balloon, Coronary↗

Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wires.

Bifurcation lesions can be technically demanding to manage, and even in the era of drug eluting stents, their procedural success is variable. The use of the crush technique followed by "kissing" balloon postdilatation has been shown to improve the overall outcome. However, crossing the crushed stent is essential to allow performance of a final dilatation with "kissing" balloons and is regarded as the main Achilles' heel of this technique. In this report, we describe the first reported, planned procedure to use a magnetic navigation system to steer a wire through the crushed stent to use "kissing" balloons that had previously failed with conventional wires.

Angioplasty, Balloon, Coronary↗

On understanding the power of judgement in percutaneous coronary intervention.

AIM: Explain how research can advance the state-of the- practice in percutaneous coronary intervention (PCI). METHODS AND RESULTS: Identifying the success factors of PCI; identifying decision- making performance (power of judgement) as the factor that could be advanced faster than is currently the case; explaining why and how such advancement needs a different research approach than those currently pursued in medical research; presenting initial results of this approach in the form of a set of basic concepts (pivoting around risk) that are useful for describing the decision-making process during a PCI. CONCLUSION: Building a terminology (ontology) of PCI decision-making concepts and then eliciting expert knowledge about the decision-making process itself are promising ways of advancing the teachability of PCI and hence the state-of-the practice.

Angioplasty, Balloon, Coronary↗