High-performance liquid chromatography versus solid-phase extraction for post-derivatization cleanup prior to gas chromatography-electron-capture negative-ion mass spectrometry of N1,N3-bis-(pentafluorobenzyl)-N7- (2-[pentafluorobenzyloxy]ethyl)xanthine, a product derived from an ethylene oxide DNA adduct.

Abstract

N7-(2-Hydroxyethyl)xanthine (N7-HEX), as a standard, has been measured at the low picomole level by the following sequence of steps: (1) derivatization with pentafluorobenzyl bromide; (2) post-derivatization sample cleanup by reversed-phase high-performance liquid chromatography (HPLC) or silica solid-phase extraction; and (3) separation/detection by gas chromatography electron-capture negative-ion mass spectrometry (GC-ECNI-MS). The average yield of product from the two sample cleanup procedures applied to 95 pg (0.48 pmol) of N7-HEX was comparable: 60% for HPLC; 56% for solid-phase extraction. The reaction blanks (0 pg N7-HEX) showed an interfering GC-ECNI-MS peak after HPLC cleanup. This problem was not encountered with solid-phase extraction, which, along with its greater convenience, made it the preferred technique for post-derivatization sample cleanup.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Saha, R W Giese. 1993-01-15. High-performance liquid chromatography versus solid-phase extraction for post-derivatization cleanup prior to gas chromatography-electron-capture negative-ion mass spectrometry of N1,N3-bis-(pentafluorobenzyl)-N7- (2-[pentafluorobenzyloxy]ethyl)xanthine, a product derived from an ethylene oxide DNA adduct.. https://doi.org/10.1016/0021-9673(93)80351-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Pressure-induced retention variations in reversed-phase alternate-pumping recycle chromatography.

The progressions of peak width and peak separation in reversed-phase alternate-pumping (AP) recycle chromatography are found to be inconsistent with conventional chromatographic theory. These discrepancies are explained by subtle pressure-induced variations of solute retention that become amplified by AP recycling. The presence of these retention variations is demonstrated by multiply injecting a single solute into an AP system at offset times. As the serially injected peaks are recycled, the separation time between the peaks is shown to vary significantly, indicating that the retention of the solute is dependent upon the position of the peak. A new model of chromatographic retention that appropriately accounts for this variable retention is presented. When this retention model is applied to an AP system for the binary separation of phenylalanine and a pentadeuterated phenylalanine, the model accurately describes the experimentally observed progressions of peak width and peak separation. Furthermore, the retention model predicts that the improvement of resolution in AP recycling closely matches the expectations of conventional theory, so the effectiveness of AP recycling is not significantly compromised by the variations in retention.

Chromatography, High Pressure Liquid

Axial nonuniformities and flow in columns for capillary electrochromatography.

Unlike in capillary zone electrophoresis and microscale high-performance liquid chromatography, columns in capillary electrochromatography (CEC) have discontinuities of the electric field strength and the flow velocity at the interface of the packed and open segments of the column. The goal of the present work is to offer a framework for measuring and interpreting the relevant electrochromatographic parameters such as the electric field strength, the potential drop, and the flow velocity in the packed segment of a CEC column. This would help us gain further insight in the electrochromatographic process and facilitate the design of CEC separation technology and comparison of data from different sources. First, the flow of ions that is governed by the conservation of current is analyzed and the potential drop across the packed and open segments of the column calculated. Then, conservation of volumetric flow rate is used to calculate the flow velocities through the two segments and, further, to estimate the net flow velocity through such a column. To satisfy the mass conservation law, in most cases a "flow-equalizing intersegmental pressure", which is different from the pressures at the two ends of the column, develops at the interface of the packed and the open segments. The intersegmental pressure, induced to equalize the flow rates in the two segments, has been shown to have a significant effect on the magnitude as well as the radial distribution of the flow velocity in the open segment, where the net flow becomes a mixture of electroosmotic and pressure-driven flows.

Chromatography, High Pressure Liquid

Sucrose dependence of solute retention on human serum albumin stationary phase: hydrophobic effect and surface tension considerations.

In a chromatographic system using human serum albumin (HSA) as a stationary phase, D,L dansyl amino acids as solutes, and sucrose as a mobile-phase modifier, a study on the surface tension effect of sugar on compound retention was carried out by varying the salting-out agent concentration c and the column temperature T. The thermodynamic parameters for solute transfer from the mobile to the stationary phase were determined from linear van't Hoff plots. An enthalpy-entropy compensation study revealed that the type of interaction between solute and HSA was independent of the molecular structure of the dansyl amino acids and the mobile-phase composition. An analysis of the experimental variations in the retention factor and the enantioselectivity values with c was performed using a theoretical model. It was shown that the decrease in solute retention accompanying the sucrose concentration increase was principally governed by a structural rearrangement of the binding cavity due to the increased surface tension effects. The cavity apolar residues were assumed to fold out of contact with the medium in order to reduce the surface area accessible to sucrose molecules, thus implying a restriction of the curvature radius of the cavity. Such behavior caused a decrease in the hydrophobic interaction for ligand binding on HSA explaining the observed thermodynamic parameter trends over the sucrose concentration range.

Chromatography, High Pressure Liquid