Two hundred and sixty-seven eyes which underwent peripheral iridectomy for presumed angle-closure glaucoma were investigated. The diagnosis of angle-closure glaucoma was confirmed postoperatively in 258 eyes, in 201 of which the intraocular pressure became normal without further treatment and in 57 of which the postiridectomy IOP was elevated because of visible damage to the anterior chamber angle. Three eyes had open-angle glaucoma with a narrow angle. Six eyes had possible mixed (combined mechanism) glaucoma (2-2%). Mixed glaucoma is a rare, fortuitous combination of open-angle and angle-closure glaucoma rather than a distinct entity, and it might be advisable to avoid the term, which tends to be used for primary glaucomas of uncertain classification.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S W Hyams, C Keroub, E Pokotilo. 1977. Mixed glaucoma.. https://doi.org/10.1136/bjo.61.2.105. https://pubmed.health/record/pubmed%3A843504/mixed-glaucoma

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite PubMed Health by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Do scleral flap dimensions influence reliability of intraocular pressure control in experimental trabeculectomy?

AIM: To compare the effect on intraocular pressure (IOP) of large vs small scleral flap size during trabeculectomy using adjustable sutures. METHODS: Trabeculectomy operations were performed on nine donor human eyes connected to a constant flow infusion with real-time IOP monitoring. Large scleral flaps (4 x 4 mm, 16 mm(2), n=12) or small scleral flaps (3 x 2 mm, 6 mm(2), n=9) were constructed over 0.76 mm(2) sclerostomies. For each procedure, equilibrium IOP was measured following tight closure with two four-throw adjustable 10-0 nylon sutures. RESULTS: Five scleral flaps were thin or poorly constructed; four of these were in the initial seven procedures, implying learning effect. These had a mean absolute IOP of 7.6 mmHg (range 2.7-12.4 mmHg) and mean relative IOP of 28.3% of baseline (range 10-45.8%) after closure. In the remaining 16 good quality procedures, mean IOP was 1.3 mmHg (range 0-3.4 mmHg) after sclerostomy, confirming minimal outflow resistance before closure. Following flap closure mean IOP was 20 mmHg (SD 4.4, range 15.5-29.3 mmHg) for large (n=8), and 18.7 mmHg (SD 3.6, 15.9-25.8 mmHg) for small (n=8) flaps (unpaired t-test, P=0.26). Mean IOP (% baseline) was 71.6% (SD 8.4, range 60.6-86.6%) and 66% (SD=12.7, 46.8-86.6%) for large and small flap groups, respectively (unpaired t-test, P=0.2). CONCLUSIONS: Well-constructed scleral flaps of both sizes were able to support an average IOP at least two-thirds of baseline, and both had similar absolute IOP levels. Errors in flap construction resulted in loss of IOP control. Smaller flap size does not appear to compromise control of early postoperative IOP using adjustable sutures.

Glaucoma↗