Sampling requirements for dynamic cardiac PET studies using image-derived input functions.

Abstract

The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R R Raylman, J M Caraher, G D Hutchins. 1993. Sampling requirements for dynamic cardiac PET studies using image-derived input functions.. https://pubmed.ncbi.nlm.nih.gov/8441036/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Left ventricular radial tagging acquisition using gradient-recalled-echo techniques: sequence optimization.

Myocardial tagging with magnetic resonance (MR) imaging offers unique possibilities for noninvasive left ventricular (LV) strain analysis. True three-dimensional strain analysis can be achieved with tags implemented in cardiac short axis and long axis images. Spin-echo (SE) techniques have been used for these studies. However, this approach is time-consuming: images at different phases of the cardiac cycle have to be obtained in successive measurements and hence the total number of measurements equals the number of time frames. Moreover, the images are often degraded by flow and motion artifacts. The purpose of this study was to optimize a faster and more robust MR tagging sequence for use on a clinical whole-body 1 T MR system with optimal persistence of the tags during the entire cardiac cycle. The tagging pulses were implemented in gradient-recalled-echo (GRE) sequences and compared to SE-based acquisitions. The effects of the use of flow-compensating gradients, the excitation angles, and the angles of the saturation pulses have been studied with MR signal simulations and in comparative measurements in volunteers. GRE acquisitions with flow-compensating gradients are robust techniques for myocardial tagging acquisitions. Use of optimized flip angles and saturation pulses can significantly improve delineation of the tag and can be used up to at least 700 ms after the R-wave. Therefore, LV tagging with GRE acquisitions using optimized MR parameters is a robust and promising technique.

Heart

[Radiation dosage of various CT techniques in diagnostic lung imaging].

Introduction of the computed tomography index CTDI and the multiple scan average dose (MSAD) has led to standardization of the dose description in CT examinations. Despite the use of these dose parameters, many different dosages are reported in the literature for different CT methods. In addition, there is still a wide range of radiation dosimetry results reported for conventional CT, helical CT, and HRCT used in chest examinations. The variations in dosage are mainly due to differences in factors affecting the dose, i.e. beam geometry, beam quality, scanner geometry ("generation"), and operating parameters. In addition, CT dosimetry instrumentation and methodology make a contribution to dosages. Recent studies calculating differences in factors affecting dosage and CT dosimetry and using similar operating parameters, show similar results in CT dosimetry for conventional and helical CT. On the other hand, dosages for HRCT were greatly reduced. This was mainly caused by narrow beam collimation and increasing section spacing.

Heart

Subclinical thyroid disease.

Widespread use of improved measurements for serum thyroid hormones and thyroid-stimulating hormone (TSH) has resulted in characterization of the syndromes of subclinical hypothyroidism, characterized by normal free T4 estimate and raised serum TSH, and subclinical hyperthyroidism, in which patients have normal serum free T4 estimate and decreased serum TSH. Therapy for these two disorders in generally recommended but must be individualized according to the patient's general medical condition. Additional studies are needed to assess the benefits of treatment. This report reviews subclinical hypothyroidism and subclinical hyperthyroidism, describing their causes, diagnostic criteria, complications, and indications for treatment. A brief review of testing for thyroid function is presented, and each of the subclinical disorders is compared with the classic syndromes of hypothyroidism and hyperthyroidism.

Heart