PubMed HealthSearch

PubMed · 8450746

Dissecting and implementing STEAM spectroscopy.

Abstract

A rapid, simple method for constructing a site-specific STEAM sequence from a basic Hahn three-pulse sequence is presented. The method assures maximum signal available from the hardware.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

W R Riddle, S J Gibbs, M R Willcott. 1993. Dissecting and implementing STEAM spectroscopy.. https://doi.org/10.1002/mrm.1910290314

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

(110) HREM of interfacial structures in semiconductor hetero-structures.

We have established a (110) cross-sectional high-resolution transmission electron microscopy (HREM) method to observe atomic structures of semiconductor hetero-interfaces. We show theoretically that the semiconductors in a hetero-structure exhibit strong contrast for an EM specimen thickness near their extinction distances, allowing atomic-scale observations of the interfacial structures between them. Furthermore, to obtain a clear HREM image, an EM specimen preparation technique is developed in which chemical etching is used to remove ion milling artifacts. This HREM method allows edge-on imaging of interfaces formed along the (110) direction; observations of atomic steps at AlAs/GaAs interfaces and a chemically ordered structure at Si/Ge interfaces are demonstrated.

Image Enhancement

Quantitative video microscopy.

Obviously there are many variations and embellishments on the topic of quantitating your image. I have tried here to offer you a very practical guide which highlights some of the critical issues paying particular attention to problems which can prevent or compromise your success. These include: errors due to aspect ratio, use of automatic camera settings, improper setting of dynamic range, and use of integer arithmetic. Further information can be found in several other chapters in this volume as well as in the references below. Additionally you shouldn't overlook the technical manuals which come with your video systems. The field of video microscopy has evolved as a cooperative effort between academia and industry. As a result you will find that many of the technical support personnel from microscope, video, and image processing companies are well versed on the issue of video imaging in biology and are more than willing to assist you.

Image Enhancement

Phantoms and automated system for testing the resolution of ultrasound scanners.

Tissue-mimicking phantoms and an automated system have been developed for testing the resolution performance of ultrasound scanners by determining detectability of low to higher contrast spherical lesions over the entire depth of field. Axial, lateral and elevational resolutions are accounted for simultaneously and equally. Tissue-mimicking spherical simulated lesions are either 3 or 4 mm in diameter and have one of four different intrinsic material contrasts. For each diameter and contrast, there is a set of 109 lesions in a regular array with coplanar centers extending from 0.5-15.5 cm in depth. With the scan slice superimposed on the spheres, the image is frame-grabbed for automated analysis. A diameter-dependent lesion signal-to-noise ratio is computed for each pixel position in the image, excluding a 5-mm boundary. Two universal thresholds, resulting from maximization of agreement between the automated system and human observers, give rise to a depth range, or "resolution zone", over which detection exists for each type lesion.

Image Enhancement