PubMed HealthSearch

PubMed · 8461672

Looking through a bubble.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Gray. 1993-01-30. Looking through a bubble.. https://doi.org/10.1136/bmj.306.6873.337-b

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Adsorption from a one-dimensional lattice gas and the Brunauer-Emmett-Teller equation.

An exact treatment of adsorption from a one-dimensional lattice gas is used to eliminate and correct a well-known inconsistency in the Brunauer-Emmett-Teller (B.E.T.) equation-namely, Gibbs excess adsorption is not taken into account and the Gibbs integral diverges at the transition point. However, neither model should be considered realistic for experimental adsorption systems.

Gases

Pressure sore in a patient who underwent repair of a retinal tear with gas injection.

PURPOSE: To demonstrate a pressure sore following strict head positioning in a patient who underwent encircling band, vitrectomy and gas injection. METHODS: A male patient was admitted to the hospital with a large posterior horseshoe tear in the inferior temporal retina with severe vitreous traction and retinal detachment. Encircling band, vitrectomy cryotherapy and gas injection was performed. After surgery the patient was instructed to sit in a face-down position. RESULTS: A pressure sore resulted from prolonged immobility of the right elbow due to face-down positioning following encircling band, vitrectomy and gas injection. CONCLUSION: A patient may rarely have compulsive personality traits that result in extreme compliance to the physician's recommendations; therefore, general instructions given for head positioning should include permission for a change in position when required, at least for brief periods of time.

Gases

[Clinical measurement of intraocular gas].

BACKGROUND: Increased use of gases in retinal/vitreous surgery requires a good clinical estimate of intraocular gases. This is needed, if a supplement of gas is intended, its disappearance to be predicted (e.g. to 10% to permit travelling by plane) or the amount to be calculated to cover a break. Clinical estimation of gas in the pupil is limited by its size. Accuracy of pupil measurements will be tested and compared with experimental results obtained by estimating the level of gas meniscus at the retina. MATERIALS AND METHODS: Ten cadaver eyes (5 phakic, 4 aphakic, 1 pseudophakic) were fixed in a plastic mold, vitrectomized and injected with multiple randomized volumes of air. Two observers measured the level of meniscus in disc diameters above or below the superior margin of disc and then anteriorly in the pupil in millimeters from the superior limbus. Measurements were converted to milliliters through tables constructed on mathematical models of the phakic and aphakic eye. RESULTS: Observations at the retina and in the pupil were equally accurate for intermediate gas volumes, for which the meniscus fell within the pupil (P = 0.372). Measurements at the retina proved less vulnerable to error induced by misalignment of the observer's eye. Above the pupil observations at the retina were still reliable for small bubbles up to 4 dd above the disc (error < 5% in the aphakic, < 10% in the phakic eye). Below the pupil observations at the retina yielded a result increasing less than the injected volume because of refraction at the anterior segment gas interface (error > 10% of the ocular volume). CONCLUSION: Observations of the level of gas meniscus at retina with indirect ophthalmoscopy is an accurate method for estimating intraocular gas volumes. It extends the range of measurement significantly beyond the pupil. Tables based on a mathematical model convert disc diameters to milliliters.

Gases