PubMed HealthSearch

PubMed · 8468341

A static dynamometer measuring multidirectional torques exerted simultaneously at the hip and knee.

Abstract

The function of a static dynamometer measuring torques exerted simultaneously in the different anatomical planes of the hip (flexion-extension, abduction-adduction and internal-external rotation) and knee (flexion-extension) is described. Muscular torques were calculated in real time using a desktop computer from measurements of orthogonal forces applied at two locations and the lever arm values measured in each subject. The reliability of the force transducers was explored by examining their output, using calibrated weights, on three different days. The results were identical over this period of time, indicating that the transducers are highly reliable. A mechanical simulator of a lower limb was constructed to generate specific or combined torques of known values at the hip and knee. The torques measured by the dynamometer were found to be highly concordant with the known torques applied by the simulator, indicating that the torque measurements were valid. The usefulness of the dynamometer is demonstrated by evaluating the activity of the rectus femoris and biceps femoris muscles during static efforts exerted in various directions at the hip. In addition, the mechanical action of biarticular muscles at the hip was evaluated by quantification of hip torques during efforts exerted at the knee. From these results, it has been concluded that the present biarticular and multidirectional dynamometer is a valid, reliable and precise instrument that may prove to be useful in evaluating the muscular function of the lower limb.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Bourbonnais, P Duval, D Gravel, C Steele, J Gauthier, J Filiatrault, M Goyette, B Arsenault. 1993. A static dynamometer measuring multidirectional torques exerted simultaneously at the hip and knee.. https://doi.org/10.1016/0021-9290(93)90366-m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Total internal reflection fluorescence: applications in cellular biophysics.

Molecular interactions occurring on or near cell membrane surfaces are expected to have different properties from those occurring in bulk solutions. One particularly useful technique for studying surface-associated processes at the molecular level is total internal reflection fluorescence. In this method, the evanescent field from an internally reflected excitation source selectively excites fluorescent molecules on or near a surface. Evanescent excitation has been used recently with a variety of techniques in fluorescence microscopy and spectroscopy to probe the fundamental physicochemical properties of biochemical reactions at natural or model biological surfaces. These studies are providing enhanced understanding of cellular function. Several recent developments in total internal reflection fluorescence methodology from other fields are likely to find future application in cellular biophysics.

Biophysics

152Eu depth profiles in granite and concrete cores exposed to the Hiroshima atomic bomb.

Two granite and two concrete core samples were obtained within 500 m from the hypocenter of the Hiroshima atomic bomb, and the depth profile of 152Eu was measured to evaluate the incident neutron spectrum. The granite cores were obtained from a pillar of the Motoyasu Bridge located 101 m from the hypocenter and from a granite rock in the Shirakami Shrine (379 m); the concrete cores were obtained from a gate in the Gokoku Shrine (398 m) and from a pillar top of the Hiroshima bank (250 m). The profiles of the specific activities of the cores were measured to a depth of 40 cm from the surface using low background germanium (Ge) spectrometers. According to the measured depth profiles, relaxation lengths of incident neutrons were derived as 13.6 cm for Motoyasu Bridge pillar (granite), 12.2 cm for Shirakami Shrine core (granite), and 9.6 cm for concrete cores of Gokoku Shrine and Hiroshima Bank. In addition, a comparison of the granite cores in Hiroshima showed good agreement with Nagasaki data. Present results indicates that the depth profile of 152Eu reflects incident neutrons not so high but in the epithermal region.

Biophysics