PubMed Health⌕ Search

PubMed · 8509935

[Acoustic rhinometry as method for evaluating paranasal sinuses--experimental studies].

Abstract

The potential application of acoustic rhinometry for evaluating paranasal sinuses was evaluated experimentally. In order to assess the influence of paranasal sinus volume in acoustic rhinometry, three model studies were performed. A tube made of acryle (20 cm in length, 2 cm in diameter) with a side hole was used for the first experiment. In the experiment measuring this tube with acoustic rhinometry, a difference between cases with a side hole (ex. 2 mm in diameter) and these without a side hole was observed. In the former, a more posterior tube position gave rise to an increase in the acoustic curve. In the second experiment, a syringe was was fixed to the side hole of the tube, so as that no leakage of sound wave would occur. A change in the volume of the syringe could be detected by acoustic rhinometry, even with changes as small as 1 ml. In the third experiment, the relationship between the size of the side hole and the volume of the syringe was evaluated. When the volume was less than 20 ml, the value was almost equal to the theoretical value even if the diameter of the side hole was as small as 4 mm. A larger size hole was required when the volume was increased. It was concluded that acoustic rhinometry is of possible value in assessing the paranasal sinuses, if the nasal cavity communicates with the paranasal sinuses via a large opening (e.g. in post-operative cases).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Kase, K Itimura, T Iinuma. 1993. [Acoustic rhinometry as method for evaluating paranasal sinuses--experimental studies].. https://doi.org/10.3950/jibiinkoka.96.626

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of gamma irradiation on mechanical properties of defatted trabecular bone allografts assessed by speed-of-sound measurement.

New sterilization methods for human bone allografts may lead to alterations in bone mechanical properties, which strongly influence short- and medium-term outcomes. In many sterilization procedures, bone allografts are subjected to gamma irradiation, usually with 25 KGy, after treatment and packaging. We used speed-of-sound (SOS) measurements to evaluate the effects of gamma irradiation on bone. All bone specimens were subjected to the same microbial inactivation procedure. They were then separated into three groups, of which one was treated and not irradiated and two were exposed to 10 and 25 KGy of gamma radiation, respectively. SOS was measured using high- and low-frequency ultrasound beams in each orthogonal direction. SOS and Young modulus were altered significantly in the three groups, compared to native untreated bone. Exposure to 10 or 25 KGy had no noticeable effect on the study variables. The impact of irradiation was small compared to the effects of physical or chemical defatting. Reducing the radiation dose used in everyday practice failed to improve graft mechanical properties in this study.

Acoustics↗

Objective and subjective evaluation of the acoustic comfort in classrooms.

The acoustic comfort of classrooms in a Brazilian public school has been evaluated through interviews with 62 teachers and 464 pupils, measurements of background noise, reverberation time, and sound insulation. Acoustic measurements have revealed the poor acoustic quality of the classrooms. Results have shown that teachers and pupils consider the noise generated and the voice of the teacher in neighboring classrooms as the main sources of annoyance inside the classroom. Acoustic simulations resulted in the suggestion of placement of perforated plywood on the ceiling, for reduction in reverberation time and increase in the acoustic comfort of the classrooms.

Acoustics↗

Analysis of effective radiating area, power, intensity, and field characteristics of ultrasound transducers.

OBJECTIVE: To characterize the ultrasound fields produced by a cohort of transducers from a single manufacturer via hydrophone and Schlieren technology. DESIGN: Descriptive study. SETTING: Measurement laboratory. PARTICIPANTS: Seven same-model ultrasound transducers from a single manufacturer. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Effective radiating area (ERA), total power, spatial average intensity (SAI), beam nonuniformity ratio (BNR), and Schlieren beam widths at 1.0 and 3.3 MHz. RESULTS: Values for ERA (1.0 MHz range, 3.62-4.38 cm(2); 3.3 MHz range, 3.74-4.76 cm(2)), total power (1.0 MHz range, 5.0-5.6 W; 3.3 MHz range, 4.7-5.7 W), SAI (1.0 MHz range, 1.2-1.4 W/cm(2); 3.3 MHz range, 1.0-1.5 W/cm(2)), and BNR (1.0 MHz range, 2.79-5.85; 3.3 MHz range, 2.51-4.56) fell within manufacturer's specifications and U.S. Food and Drug Administration (FDA) regulations. Schlieren analysis showed significantly larger beam widths at 3.3 MHz compared with 1.0 MHz and a large degree of variability in the ultrasound fields generated by the different transducers. There were no significant correlations between beam widths and ERA values. CONCLUSIONS: ERA and total power values in a test cohort exist within a range that met FDA regulations. Individual variability in ERA and total power resulted in 50% variability in SAI. This variability may help explain previous reports of heating differences between transducers.

Acoustics↗