Exploratory data analysis in two-dimensional electrophoresis.

Abstract

The use of computerized matching of proteins in the analysis of multiple two-dimensional electrophoresis (2DE) gels creates volumes of data that are readily accessible for exploratory analysis. When these data are used in health-effects studies or in studies to identify factors associated with particular diseases, hundreds or even thousands of hypotheses can be tested. Interpreting so many hypothesis tests requires some preliminary statistical evaluations of the data. In addition, prior to the preliminary statistical evaluations and subsequent hypothesis tests, accurate protein quantification and correct protein matching must be verified. In this report we present an approach used at the Centers for Disease Control to address these issues. This approach consists of a randomized experimental design incorporating replicate gels for each specimen, gel image analysis, protein matching, editing, Boolean unions of all gels to obtain correspondences and contradictions of match identification numbers, resolution of correspondences and contradictions, statistical tests to identify outliers, and finally an assessment of statistical and practical significance to focus attention on the proteins most likely to be associated with the effects under study. We illustrate our approach with data from an exploratory exposure-response study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S P Caudill, J E Myrick, M K Robinson. 1993. Exploratory data analysis in two-dimensional electrophoresis.. https://pubmed.ncbi.nlm.nih.gov/8512943/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Microchip-based capillary electrophoresis of human serum proteins.

The separation and relative quantitation of human serum proteins is important to the clinical diagnosis of various states of disease. Microchip-based capillary electrophoresis (CE) of human serum proteins offers several advantages over sodium dodecyl sulfate-poly(acrylamide) gel electrophoresis and conventional CE methods, including decreased sample consumption and analysis time and the possibility of on-chip sample manipulation (dilution, labelling, etc.). The microchip used in these studies was designed to allow for on-chip, post-separation labelling of the proteins and subsequent laser-induced fluorescence detection. 2-Toluidinonaphthalene-6-sulfonate (TNS) is a virtually non-fluorescent reagent which, upon non-covalent association with the protein and excitation at 325 nm, produces a fluorescent product with an emission maximum near 450 nm. After optimization of buffer conditions (100 mM borate with 2 mM lactate, pH 10.5), individual serum proteins (IgG to mimic the gamma zone, transferrin the beta zone, alpha-1-antitrypsin the alpha 1 zone and albumin its own zone) were successfully resolved on-chip, as was a "synthetic" serum solution composed of a mixture of all four of the previously mentioned proteins. Analysis of all five protein zones in a true human serum sample, however, has not yet been achieved on-chip due to the poor sensitivity of the TNS label for several of the serum proteins.

Blood Protein Electrophoresis

Characterisation of human serum albumin heterogeneity by capillary zone electrophoresis and electrospray ionization mass spectrometry.

Human serum albumin (HSA) preparations and HSA-containing recombinant human erythropoietin (rhEPO) formulations were analyzed by capillary zone electrophoresis. HSA was separated into several components by the addition of 1,4-diaminobutane to 20 mM sodium phosphate, pH 6.0 as electrophoretic buffer. Resolution was improved by increasing the buffer pH to 8.5. A comparative analysis of HSA preparations from three manufacturers provided evidence that this method can be used to differentiate individual preparations. The analysis of rhEPO formulations, composed largely of HSA, showed levels of heterogeneity comparable to that of HSA preparations. Electrospray ionisation mass spectrometry was used as an independent method to confirm the heterogeneous nature of HSA.

Blood Protein Electrophoresis